Juniper Networks J-Series manual Summary of Key Media Gateway Information Output Fields

Models: J-Series

1 332
Download 332 pages 610 b
Page 174
Image 174

J-series™ Services Router Administration Guide

show tgm dynamic-call-admission-control

show tgm fpc slot-numbermedia-gateway-controller

show tgm fpc slot-numberdsp-capacity

show tgm telephony-interace-module status

Table 79 on page 152 summarizes key output fields in media gateway information displays.

Table 79: Summary of Key Media Gateway Information Output Fields

Field

Values

Dynamic Call Admission Control Information

Reported Bearer

Maximum bandwidth available for voice traffic

Bandwidth Limit

on the Services Router.

Interface Name

Name of interface on which dynamic CAC is

 

configured.

 

(See the interface naming conventions in the

 

J-series Services Router Basic LAN and WAN Access

 

Configuration Guide.)

State

Link state of the interface: Up or Down.

Activation Priority

Activation priority configured on the interface.

Bearer Bandwidth

Maximum bandwidth available for voice traffic

Limit (Kbps)

on the interface.

Telephony Gateway Module Information

Media Gateway

IP addresses of the MGCs configured in the MGC

Controller (MGC) List

list for the TGM550.

Slot state

Online and offline status of the telephony interface

 

modules (TIMS).

Offline Reason

Reason for offline status: Busy Out or Out of

 

resources.

Additional Information

If dynamic CAC is configured on more than one active interface, the TGM550 reports the bearer bandwidth limit (BBL) of the active interface with the highest activation priority.

If more than one active interface has the same activation priority, the BBL is reported as the number of those interfaces times their lowest BBL. For example if two interfaces with the same activation priority have BBLs of 2000 Kbps and 1500 Kbps, the RBBL is 3000 Kbps (2 x 1500 Kbps).

The operational state is the physical state of the interface. If the interface is physically operational, even if it is not configured, the operational state is Up. An operational state of Down indicates a problem with the physical interface.

152Using the Monitoring Tools

Page 174
Image 174
Juniper Networks J-Series Summary of Key Media Gateway Information Output Fields, Telephony Gateway Module Information