Chapter 9: Configuring and Monitoring Alarms

Table 89: Interface Alarm Conditions (continued)

Interface

Alarm Condition

Description

Configuration

 

 

 

Option

Services

Services module hardware

A hardware problem has occurred on the Services

hw-down

 

down

Router's services module. This error typically means

 

 

 

that one or more of the CPUs on the module has

 

 

 

failed.

 

 

Services link down

The link between the Services Router and its services

linkdown

 

 

module is unavailable.

 

 

Services module held in reset

The Services Router's services module is stuck in

pic-hold-reset

 

 

reset mode. If the services module fails to start up

 

 

 

five or more times in a row, the services module is

 

 

 

held in reset mode. Startup fails when the amount

 

 

 

of time from CPU release to CPU halt is less than

 

 

 

300 seconds.

 

 

Services module reset

The Services Router's services module is resetting.

pic-reset

 

 

The module resets after it crashes or is reset from

 

 

 

the CLI, or when it takes longer than 60 seconds to

 

 

 

start up.

 

 

Services module software down

A software problem has occurred on the Services

sw-down

 

 

Router's services module.

 

E3

Alarm indication signal

The normal E3 traffic signal contained a defect

ais

 

 

condition and has been replaced by the AIS. A

 

 

 

transmission interruption occurred at the remote

 

 

 

endpoint or upstream of the remote endpoint. This

 

 

 

all-ones signal is transmitted to prevent

 

 

 

consequential downstream failures or alarms.

 

 

Loss of signal

No remote E3 signal is being received at the E3

los

 

 

interface.

 

 

Out of frame

An out-of-frame (OOF) condition has existed for

oof

 

 

10 seconds. This alarm applies only to E3 interfaces

 

 

 

configured in frame mode. The OOF failure is cleared

 

 

 

when no OOF or LOS defects have occurred for

 

 

 

20 seconds.

 

 

Remote defect indication

An AIS, LOS, or OOF condition exists. This alarm

rdi

 

 

applies only to E3 interfaces configured in frame

 

 

 

mode.

 

Alarm Overview 169

Page 191
Image 191
Juniper Networks J-Series manual Hw-down, Linkdown, Pic-hold-reset, Pic-reset, Sw-down, Los, Oof, Rdi