J-series™ Services Router Administration Guide

System Alarm Conditions and Corrective Actions

Table 91 on page 172 lists the two preset system alarms, the condition that triggers each alarm, and the action you take to correct the condition.

Table 91: System Alarm Conditions and Corrective Actions

Alarm Type

Alarm Condition

Corrective Action

Configuration

The rescue configuration is not set.

Set the rescue configuration. For instructions,

 

 

see the J-series Services Router Basic LAN and

 

 

WAN Access Configuration Guide.

License

You have configured at least one software

 

feature that requires a feature license, but

 

no valid license for the feature is currently

 

installed.

 

NOTE: This alarm indicates that you are in

 

violation of the software license agreement.

 

You must install a valid license key to be in

 

compliance with all agreements.

Install a valid license key. For instructions, see the Getting Started Guide for your router.

Before You Begin

Before you begin configuring and monitoring alarms, complete the following tasks:

Establish basic connectivity. See the Getting Started Guide for your router.

Configure network interfaces. See the J-series Services Router Basic LAN and WAN Access Configuration Guide.

Configuring Alarms with a Configuration Editor

To configure interface alarms on a Services Router, you must select the network interface on which to apply an alarm and the condition you to trigger the alarm. For a list of conditions, see “Interface Alarm Conditions” on page 167.

To configure interface alarms:

1.Navigate to the top of the configuration hierarchy in either the J-Web or CLI configuration editor.

2.Perform the configuration tasks described in Table 92 on page 173.

3.If you are finished configuring the network, commit the configuration.

4.To verify the alarms configuration, see Displaying Alarm Configurations on page 175.

5.To check the status of active alarms, see “Checking Active Alarms” on page 174.

172Before You Begin

Page 194
Image 194
Juniper Networks J-Series Configuring Alarms with a Configuration Editor, System Alarm Conditions and Corrective Actions