Chapter 14: Configuring RPM Probes

Table 142: Configuring TCP and UDP Probes (continued)

Task

Configure the RPM test tcp-testfor the RPM owner customerC.

The sample RPM test is a TCP probe with a test interval (probe frequency) of 5, a probe type of tcp-ping, and a target address of 192.162.45.6.

Configure the destination interface.

NOTE: On Services Routers the destination interface must be an lt services interface.

J-Web Configuration Editor

1.On the Rpm page, select customerC.

2.In the Test box, click Add new entry.

3.In the Name box, type tcp-test.

4.In the Test interval box, type 5.

5.In the Probe type box, select tcp-ping.

6.In the Target box, select the Yes check box, and click Configure.

7.In the Target type box, select Address.

8.In the Address box, type

192.162.45.6.

9.Click OK.

In the Destination interface box, type

lt-0/0/0

CLI Configuration Editor

1.From the [edit] hierarchy level, enter

edit services rpm probe customerC

2.Enter

set test tcp-test probe-frequency 5

3.Enter

set test tcp-test probe-type tcp-ping

4.Enter

set test tcp-test target address 192.162.45.6

Enter

set test tcp-test destination-interface lt-0/0/0

Configure port 50000 as the TCP port to

In the Destination port box, type 50000.

which the RPM probes are sent.

 

 

Router B Configuration

 

 

Navigate to the Services>RPM level in

1.

In the J-Web interface, select

the configuration hierarchy.

 

Configuration>View and

 

 

Edit>Edit Configuration.

 

2.

Next to Services, click Configure

 

 

or Edit.

 

3.

Next to Rpm, select the Yes check

 

 

box.

 

4.

Click Configure.

Configure Router B to act as a TCP

1.

Next to Probe server, click

server, using port 50000 to send and

 

Configure.

receive TCP probes.

2.

In the Tcp box, click Configure.

 

 

3.

In the Port box, type 50000.

 

4.

Click OK.

Enter

set test tcp-test destination-port 50000

From the [edit] hierarchy level, enter

edit services rpm

Enter

set probe-server tcp port 50000

Configuring RPM with a Configuration Editor 281