Specifications
Supply water pressure
This system conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and substantiated by test data.
Installations In The Commonwealth Of Massachusetts: The Commonwealth of Massachusetts requires instal- lation be performed by a licensed plumber. Plumbing code
Troubleshooting
Problem: Taste and/or Odor.
Cause: Pre & Post filter expended. Correction: Replace the filter cartridges. See Page 9.
Cause: System contaminated.Correction: Sanitize system. Call
Problem: Faucet LED indicator light does not function after battery change.
Cause: | Battery dead. | Correction: | Replace with new battery. See Page 9. |
|
|
|
|
Cause: | Battery installed incorrectly.. | Correction: | Install battery correctly. |
|
|
|
|
Problem: Water leaks at push connect fittings.
Cause: | Tubing not pushed in all the way. | Correction: Push Tubing all the way into fittings. See Page 8. | |
|
|
|
|
Cause: | Tubing not cut square. | Correction: Cut tubing square. See Page 8. | |
|
|
|
|
Cause: |
| Correction: | Remove tube from connection. Remove nicked portion |
Tubing nicked. | by cutting tube to shorter length. Reinsert in connection | ||
|
|
| See Page 8. |
Cause: |
| Correction: | Remove tube from connection. Remove problem area |
Outer tubing surface not smooth. | by cutting tube to shorter length. Reinsert in connection | ||
|
|
| See Page 8. |
Questions? Call The Kenmore Water Line