BEFORE CALLING FOR SERVICE
Check the following list to be sure a service call is really necessary A quick reference to this manual may help you avoid an unneeded service call.
THE AIR | CONDITIONER WILL NOT OPERATE |
;heck if | ...Then... |
Wallplugdisconnected.
Housefuseblownorcircuitbreakertripped. MODEselectorisOFFposition. UnitwasturnedoffbymovingTEMPControltoa warmer andthenimmediatelyturningbackto acoldersetting. Unitwasturnedoffandthenontonquickly. TEMPControlsetwarmerthanroomtemperature.
Pushplugfirmlyintowalloutlet. Replacefusewithtimedelaytypeorresetcircuitbreaker.
TurnMODEselectorto thedesiredCOOLsetting. Waitapproximately3minutes.Listenfor compressortostart.
Turnunitoffandwait3 minutesbeforerestarlJng.
TurnTEMPControlclockwiseto acoldersetting(highernumber).
AIR FROM UNIT DOES NOT FEEL COLD ENOUGH.
Check if... | Then... |
MODEselectorina LOWCOOLposition. | Turnselectortoa h_herCOOLposition |
TEMPControlsettonwarm(lowernumber) | TurnTEMPControldeckwisetoacoldersetting. |
Roomtemperaturebelow70°F(21°C) | Coolingmaynotoccuruntilroomtemperaturerisesabove70°F(21°C). |
Temperaturesensingtubetouchingcoldceil, | Straightentubeawayfromcoil. |
locatedbehindairfilter. |
|
Check if... | Then... |
Outdoortemperaturebelow70°F(2!°C). | Todefrostthecoil,setselectorto FANpositionThen,turn.TEMPControl |
Airfiltermaybedirty. | clockwiseto awarmersetting. |
Cleantilter RefertoMaintenancesectionof owner'smanualTodefrost,. | |
| setselectorto FAN, |
Todefrosttheceil,setselectorto aFANpositionThen,setTEMPControl. | |
| toawarmerposition. |
Check if...
Dirtyair
TEMPControlsettonwarm.
Frontofunitis blockedbydrapes,blinds,furniture, etc.Airdistribution restricted.
Doors,windows,registers,etc.open.ColdairescaF_. Unitrecentlyturnedoninhotroom.
Then...
Cleanairfilter.Referto Maintenancesectionof owner'smanual.
TurnTEMPControlclockwisetoacoldersetting.
Clearblockageinfrontof unit.
Closedoors,windows,registers,etc.
Allowadd_ timetoPernovestoredheatfromwalls,ceiling,floor,andfumiture.
THE AIR CONDITIONER TURNS ON AND OFF RAPIDLY. |
|
| ||
Check | if... | Then... |
|
|
I Outsidetemperatureisextremelyhot. | I SetMODEonHIGHspeedtobringairpastcoolingcoilsmerefrequently. I | |||
|
|
|
| m |
NOISE WHEN UNIT IS COOLING. |
|
|
| |
Check | if... | Then... |
|
|
Air movementSoundis tooioed. | Turnselectorto LOWsetlJng. |
| ||
Soundoffanhittingwater- moistureremovalsystem. |
|
| / | |
Thisisnormalwhenhurniddyis highClosedoors,windows,andregisters.. | ||||
Windowvibration- poorinstallation. | Referto installationinstructionsorcheckwi_ installer. |
| ||
WATER DRIPPING INSIDE WHEN UNIT IS COOLING. |
|
| ||
Check | if... | Then... |
|
|
Theairconditionerisimproperlyinstalled. | "nitairconditionerslightlytotheoutsidetoallowwaterdrainageReferto. | |||
|
| installationinstructionsCheckwithinstaller. | . |
|
WATER DRIPPING OUTSIDE WHEN UNIT IS COOLING. |
|
| ||
Check | if... | Then... |
|
|
TheunitisremovinglargequantityofmoistureThisisnormalduringexcessivelyhumiddays. fromhumidroom.