Foryourconvenience, all three filters (Pro- Filter, Washable
6. Plug in the power cord to a we1outlet |
and turn on the unit, |
6. Do not dry the two | 8, Replace the filter ¢_ssette and front |
unit will be sufficient to drythem. | panel as described in Replacement |
| Procedure. |
packaged replacement cassette.
For optimum unit efficiency, wash the Pre- Filter and Washable
Filter as described below (Filter Cleaning) every three months.
Do not wash and reuse the True HEPA
Fitter_tt will not work effectively.
WARNING: Before replacing or cleaning t any filters, make sure to remove the powerplug from the wa out et.
7. To turn off the CHANGE FILTER |
INDICATOR, press the FUNCTION and |
OFF ]IMER buttons at the same time for |
five seconds; the CHANGE FILTER |
INDICATOR will flash five times and turnoff. |
Filter Cleaning
we recommend cleaning the
and tile Nano_Silver/CarbonFilter (C) every three monthswith normal use, The interval
between cleanings will vary based on room conditions.
7.Replace each filter in the cassette frame by insertingone tong edge first, then
snapping intoplace by pushing sideways and down at the same time. Make sure
both fittersare completelyinside the cassette frame and secured by the short tabs. If a filter Is on top of one or more tabs, pulloutward,slightly flexing the
cassette frame, while gently pushing down on the edge of {he filter,
gPlug in the power card to a wall outtet and turn on the unit.
Note: Neveratlem!_to removetheTrue HEPA1 Filterfrom _e cassetteframe. Neverattemptto cleanthe Tlue HEPA Filler.Replaoetheentire casselteonlywhenCHANGE FILTERalert t
activates.(Model85500mplacoment#85501; I
Model85501 replacement#85511) | j |
1.Remove the front panel and filter
Replacement Procedure
1,Remove the front panel by pullinggently on the sliver tabs
located on each side of the unit,
2.Pull out the filter cassette by grasp!rig tile black tabs located
on each side.
3.Remove the plasticwrap from the new filter cassette.
4.Place the new filter cassette in the main unit,
5, Replace the front panel.
cassette as described in Replacement Procedure.
2, Remove the
while lifting the
cleanii_
3.Lightty vacuum the
4.To remove the Washable
outward while pulling up on the gray lab. When the first corner is released, pulloul on the olher tall frame tab while
continuingto pullup on the gray tab. When one long edge of the filter is free, slide out for cleaning,
5, Wash the filterin warm water with a mild
householddetergent, Rinse, and shake off excess water,
CASSETTE
SHORT TABS
FRONT SIDE
PowerP_g
GRAY TAB
! CASS ETT_
LONG TAB
PlasrnaDoctorTM
Display Panel
I)C Motor
Washable Nano-
SiivertCarbon F_tler
Filler Cassette with 1"rueHEPA Filter inside
-Front Panel
Remme
CanI_l
Air Outlet C_d_
TOP SIDE