SECTION5 | SERVICE TECH. INFORMATION |
A. TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) com-
puter has a
tion for the electrical system, ex- E r F _ _ cept for input power and water
meter. The computer monitors electronic compo-
nents and circuits for correct operation. If a malfunc-
tion occurs, an error code appears in the faceplate display.
MOST LIKELY _"
CODE_"
The chart below shows the error codes that could appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SELECT but-
ton. SELECT remains operational so the service per-
son can make the MANUAL INITIATED ELEC-
TRONIC DIAGNOSTICS (below) to further isolate the defect, and check the water meter.
POSSIBLE DEFECT
_ LESS LIKELY
Err1, Err3, | motor inoperative / wiring harness or connection to switch / position switch / valve defect causing |
Err4 | hiqh torque |
Err5 | faceplate timer (PWA) |
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug transformer from outlet 2. Correct
defect 3. Plug in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
| MANUAL | INITIATED | ELECTRONICS | ||
| DIAGNOSTICS |
|
|
| |
[] | enter | diagnostics, | press | the | SELECT button |
| |||||
| until 000 | - - shows | in the | display. |
|
NI3 1"3
UUU- -
A.The first 3 digits indicate water meter operation as follows:
000 (steady) = Soft water not in use, and no
flow through the meter.
--OPEN A NEARBY SOFTWATER FAUCET--
000 to 199 (continual) = Repeats display for each
gallon of water passing through the meter.
If you don't get a reading in the display with faucet
open, pull the sensor from the vane outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, unhook the in and out plumbing and check the turbine for binding.
POSITION
SWITCH
SENSOR
HOUSING
RBINE
lINE
SUPPORT AND
SHAFT
VALVE
B. The letter (P) and dashes indicate POSITION
switch operation. If the letter appears, the switch is closed. If the dashes show, the switch is open.
Use the RECHARGE button to manually ad- vance the vane into each cycle and check correct switch operation.
Problems, Questions? Call