Controls

Operations of the following control and switches are required in accordance with the center unit and speakers connected with this unit.

SPEAKER LEVEL INPUT

FILTER

OPERATION

 

 

LEFT

RIGHT

OFF LPF

STEREO

MONO(Lch)

 

 

LINE IN

 

 

 

0.5

0.3

L

R

 

 

 

1.0

 

 

 

 

 

GND

MIN

MAX

 

 

 

 

 

INPUT

 

 

 

 

 

SENSITIVITY(V)

 

 

 

KAC-726

1 2

3 4

5

6

KAC-526X

 

 

 

 

 

 

POWER IN

 

 

 

FUSE(20A x 2)

GND

 

BRIDGED

 

BATT

P.CON(REMOTE)

LEFTRIGHT

SPEAKER OUTPUT

POWER AMPLIFIER

KAC-726

7

8 9 0

!

 

 

POWER IN

 

 

 

GND

BRIDGED

 

FUSE(15A) BATT

P.CON(REMOTE)

LEFTRIGHT SPEAKER OUTPUT

POWER AMPLIFIER

KAC-526X

7 8 9 0

!

 

1RCA cable ground lead terminal

2FILTER switch

These switches allow filtering of the speaker output signals.

LPF (Low Pass Filter) position

Only frequencies of 80 Hz or lower are output. (Frequencies above 80 Hz are cut.)

The Lch and Rch will be mixed before output even if the operation switch is set to STEREO.

OFF position

The original sound without filtering is output.

3OPERATION switch

This switch allows selection of the amplification method of input signals.

STEREO position

The amplifier can be used as a stereo amplifier.

MONO (Lch) position

Amplifies the signal input from the left side only. Set to this position and make bridged connections to use as a high-power monaural amplifier. (The input right signal is not output.)

4INPUT SENSITIVITY control

Set this control according to the pre-output level of the center unit connected with this unit, or to the maximum power output of the genuine- accessory car stereo.

Use the diagram on the right as a guide.