Controls

NOTE

The control panel locates under the front side cover. Remove the cover to access to its controls for adjustment. (See page 3)







100

150

25

30

 

1

 

20

35

2

0.5

70

 

 

3

 

 

 

0.3

50

200

15

40

4

 

[MIN] 5

0.2 [MAX]

 

LPF

 

ISF

INPUT

FREQUENCY[Hz]

FREQUENCY[Hz]

SENSITIVITY[V]

LINE OUT

FILTER

ON



OFF

Z



Remote controller

THERMAL MANAGEMENT

PROTECTION

 

 

BATT.

GND

 

 

 

 

 

REMOTE

L

 

 

 

 

 

 

 

 

R

FUSE [30Ax3]

P.CON

SPEAKER OUTPUT

 

LINE IN LINE OUT

   



1Fuse (30 A × 3)

NOTE

If you can’t find the specified capacity fuse at your store etc., consult your Kenwood dealer.

2Battery terminal

3Power control terminal

Controls the unit ON/OFF.

NOTE

Controls the unit power. Be sure to connect it with all the systems.

4Ground terminal

5Speaker output terminals

As this unit accepts speakers with a minimum impedance of 1 ohm, connect speakers with 1-ohm or higher impedance to these terminals.

6REMOTE terminal

Connects the Remote cable.

NOTE

Use the Remote cable of the accessory.

7LINE IN terminal

8LINE OUT terminal

The audio signal set with the LINE OUT FILTER switch will be output.

9BOOST LEVEL (Bass boost level) control

Sets the level by which the low frequency range should be boosted.

0Power indicator

-FREQUENCY (Bass boost frequency) control

Sets the center frequency around which the low frequency range should be boosted.



 

@LPF(Low-Pass Filter) FREQUENCY control

This control adjusts the frequency band output from this unit.

#ISF (infrasonic filter) control

Ultralow frequencies that cannot be reproduced even by a subwoofer speaker do not become sound but become unnecessary oscillations, which affect the sound by causing distortion, etc. Setting this control cuts the frequencies below the respective frequency.

This improves the reproduction performance of the speakers by eliminating unnecessary oscillations which will not become sound.

$INPUT SENSITIVITY control

Set this control according to the pre-output level of the center unit connected with this unit.

NOTE

For the pre-output level, refer to the <Specifications> in the instruction manual of the center unit.

%LINE OUT FILTER switch

Changing over the audio signal output to the LINE OUT terminal.

ON position:

The audio signal adjusted when setting LPF, INPUT SENSIVITY control and Bass boost (optional accessory) is output to the LINE OUT terminal.

OFF position:

The audio signal input from the LINE IN terminal is output to the LINE OUT terminal (through output).

CAUTION

The volume of the audio output to the LINE OUT terminal is different in ON and OFF position. Remember this when changing the LINE OUT FILTER switch from ON to OFF.

=THERMAL MANAGEMENT indicator

Lights this indicator when the internal temperature is high.

~PROTECTION indicator

Lights this indicator when the protection function is activated. (See page 2)

!Power indicator

When the power is turned on, the Power indicator lights.