Amplifier Control System
Display mode
You can set up the display items as follows:
1Enter Menu modePress the [MENU] button. "VOLT"/"CURR"/"TEMP"/"FAN" is displayed.
2Select a display itemPress the [2] or [3] button.The display items are switched in the following sequence.
Display | Information |
"VOLT" | Indicates the source voltage (V). |
"CURR" | Indicates the current consumption (A). |
"TEMP" | Indicates the internal temperature (°F/°C). |
"FAN" | Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF". |
NOTE
When the internal temperature is
Separate Amp Control
You can control sounds using the Amplifier Control function of the unit.
1Enter Menu mode
Press the [MENU] button.2Select the Menu item Press the [MENU] button.
The setup items are displayed approximately 1 second first, then the set values are displayed.
3Adjust the Menu item Press the [2] or [3] button.The setup items and set values are switched as follows.
Display | Range | Adjustment Item | |
"VOLT"/"CURR"/"TEMP"/"FAN" | For the operation method refer to <Display mode> | ||
"BASS" | 60/80/100/200 (Hz) | Bass Center Frequency | |
"BA G" | Bass level | ||
"BA Q" | Q1.00/Q1.25/Q1.50/Q2.00 | Bass Q Factor | |
" EXT" | ON/OFF | When the bass extend is set to ON, low frequency response is | |
extended by 20%. | |||
|
| ||
"TREB" | 10/12/15/17 (kHz) | Treble Center Frequency | |
"TR G" | Treble level | ||
"VOL" | Volume offset | ||
"TEMP" | FAHR (Fahrenheit) or | The Fahrenheit or Centigrade temperature unit can be selected for | |
CELS (Centigrade) | the Display mode. | ||
| |||
"DEFA" |
| For the operation method refer to <Default> | |
"AMP" | 0 — 7 | The ID Number you have assigned is displayed. |
|
| Indicator |
FAN | VOLT | MENU |
TEMP | CURR |
|
2 / 3
4Exit Menu modePress the [MENU] button for at least 1 second.
NOTE
When you hold down the [3] button 3 or more seconds during ID number display ("AMP"), message "MEMO" is displayed and you can register the values you have set with the Amplifier Control. To call the Amplifier Control’s values, hold down the [2] button 3 or more seconds during ID number display ("AMP"). Then, you can recall the value when message "LOAD" is displayed.
Default
Resets all values you have set to the initial (default) values.
1Enter Menu mode
Press the [MENU] button.
2Select Default mode Press the [MENU] button. Select the "DEFA" display.
3Resets the value to its defaultPress the [3] button for at least 2 seconds. Message
4Exit Menu mode
Press the [MENU] button for at least 1 second.
NOTE
Volume offset value can not be initialized.
Display Demonstration
The "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly.
Press the [MENU] button for at least 2 seconds.The indicator flashes in the Demonstration mode.
Canceling the Demonstration modePress any button to cancel the Demonstration mode.6English