15.

K-Cup® Sensor

“15: CLOSE KCUP”

door. Ejection blocks

Lower the handle

 

(unblocked)

“MODULE: BR-HEAD”

sensor!!

 

 

 

 

 

 

16.

Brew tank

“16: BREW TEMP”

 

Auto Cont. if OK

 

Thermistor @

“MODULE: HWT”

 

 

 

ambient temperature

 

 

 

17.

Pre-heat tank

“17: PREHEAT TEMP”

 

Auto Cont. if OK

 

Thermistor @

” MODULE: HWT”

 

 

 

ambient temperature

 

 

 

18.

120 Hz Clock (60

“18: 120 HZ CLOCK”

 

Auto Cont. if OK

 

Hz Power)

“MODULE: M-PCB”

 

 

19.

Heaters off

“19: HEATER LOW

 

Press Right Button

 

 

AMP?”

 

if less than 1 amp

 

 

“MODULE: POWER”

 

 

 

 

R LED blinks

 

 

20.

Brew Tank

“20: BREW 12A?”

Heating Element on

Press Right Button

 

Heating Element

“MODULES: POWER,

for 3 seconds –

if OK, Center Right

 

power

HWT”

Verify 12A

to repeat

 

 

R LED blinks

 

 

21.

Preheat Tank

“21: PRE 12A?”

Heating Element on

Press Right Button

 

Heating Element

“MODULES: POWER,

for 3 seconds –

if OK, Center Right

 

power

HWT”

Verify 12A

to repeat

 

 

R LED blinks

 

 

22.

Initial Air

“22: CW PUMP.

CWP on for 2

Clamp CWT vent

 

Pressurization with

CLAMP&PSI-M”

seconds. Verify

tube, add pressure

 

Water Pump,

“MODULE: CWP, C-

>0.25 psi

gauge. Press Right

 

Pressure transducer

PCB, LEAK”

 

Button when ready.

 

 

R LED blinks

 

 

23.

Vent Valve opening

“23: VV OPEN LO-PSI”

Vent Valve open for

Auto Continue if

 

under low pressure

“MODULE: CWT”

2 seconds – Verify

OK

 

 

 

<0.1 psi

 

24.

Full HWT air

“24: BREW PUMP

Runs Brew Pump

Press Right Button

 

Pressurization with

7PSI?”

until 7 psi. Checks

when lit and gauge

 

Brew Pump.

“MODULE: CWT,

pressure drop below

at 7 psi

 

Pressure transducer

LEAKS”

.21 psi (7 psi - 3%)

 

 

calibration

R LED blinks if 7psi

over 5s. If pass, R

 

 

 

 

LED lights.

 

25.

Half CWT

“25: VV OPEN HI-PSI”

Opens VV.

Auto Continue if

 

Pressurization by

“MODULE: CWT”

(tanks equalize)

OK

 

sharing;

 

Wait 5 seconds –

 

 

Vent Tubes

 

check for pressure 3-

 

 

Vent Valve opening

 

5 psi.

 

 

under full over

 

 

 

 

pressure

 

 

 

26.

CWT, Vent Tubes

“26: CWT LEAK”

Checks pressure drop

Auto Continue if

 

Leaks

“MODULE: CWT,

below .21 psi (4 psi)

OK

 

 

LEAKS”

5% over 5 seconds

 

 

 

B3000 SERVICE MANUAL

 

 

 

60-200807-000, REV C

 

87