14. | “14: OPEN KCUP” | Done by opening the | Raise the handle | |
| (blocked) | “MODULE: | door. Ejection blocks |
|
15. | “15: CLOSE KCUP” | sensor!! | Lower the handle | |
| (unblocked) | “MODULE: |
|
|
16. | 120 Hz Clock (60 | “16: 120 HZ CLOCK” |
| Auto Cont. if OK |
| Hz Power) | “MODULE: |
|
|
17. | PT Sanity check | “17: LOW PRESSURE | Ambient pressure | Auto Cont. if OK |
|
| CHECK” | <0.25 |
|
|
| “MODULE: CTRL- |
|
|
|
| PCB” |
|
|
18. | Initial Air | “18: CW PUMP. | CWP on for 2 | Clamp CWT vent |
| Pressurization with | seconds. Verify | tube, add pressure | |
| Water Pump, | “MODULE: CWP, C- | >0.25 psi | gauge. Press Right |
| Pressure transducer | PCB, LEAK” |
| Button when ready. |
|
| R LED blinks |
|
|
19. | Vent Valve opening | “19: VV OPEN | Vent Valve open for | Auto Continue if |
| under low pressure | “MODULE: CWT” | 2 seconds – Verify | OK |
|
|
| <0.1 psi |
|
20. | Full HWT air | “20: BREW PUMP | Runs Brew Pump | Auto Continue if |
| Pressurization with | 7PSI?” | until 7 psi. Checks | OK |
| Brew Pump. | “MODULE: HWT, | pressure drop below |
|
| Pressure transducer | LEAKS” | .21 psi (7 psi - 3%) |
|
| calibration |
| over 5s. If pass, |
|
21. | Half CWT | “21: VV OPEN | Opens VV. | Auto Continue if |
| Pressurization by | “MODULE: CWT” | (tanks equalize) | OK |
| sharing; |
| Wait 5 seconds – |
|
| Vent Tubes |
| check for pressure 2- |
|
| Vent Valve opening |
| 5 psi. |
|
| under full over |
|
|
|
| pressure |
|
|
|
22. | CWT, Vent Tubes | “22: CWT LEAK” | Checks pressure drop | Auto Continue if |
| Leaks | “MODULE: CWT, | below .21 psi (4 psi - | OK |
|
| LEAKS” | 5%) over 5 seconds |
|
23. | HW Dispense valve | “23: HWD VALVE” | Open VV. Open | Auto Continue if |
|
| “MODULE: | HWDV. Verify | OK |
|
|
| HWT <0.1 psi after 2 |
|
|
|
| seconds |
|
24. | Brew tank | “24: BREW TEMP” |
| Auto Cont. if OK |
| Thermistor @ | “MODULE: HWT” |
|
|
| ambient temperature |
|
|
|
25. | “25: PREHEAT TEMP” |
| Auto Cont. if OK | |
| Thermistor @ | ” MODULE: HWT” |
|
|
| ambient temperature |
|
|
|
26. | Heaters off | “26: HEATER LOW |
| Press Right Button |
|
| AMP?” |
| if less than 1 amp |
|
| “MODULE: POWER” |
|
|
|
| R LED blinks |
|
|
|
| B3000 SERVICE MANUAL |
| |
|
|
| 90 |