14.

K-Cup Sensor

“14: OPEN KCUP”

Done by opening the

Raise the handle

 

(blocked)

“MODULE: BR-HEAD”

door. Ejection blocks

 

15.

K-Cup Sensor

“15: CLOSE KCUP”

sensor!!

Lower the handle

 

(unblocked)

“MODULE: BR-HEAD”

 

 

16.

120 Hz Clock (60

“16: 120 HZ CLOCK”

 

Auto Cont. if OK

 

Hz Power)

“MODULE: M-PCB”

 

 

17.

PT Sanity check

“17: LOW PRESSURE

Ambient pressure

Auto Cont. if OK

 

 

CHECK”

<0.25

 

 

 

“MODULE: CTRL-

 

 

 

 

PCB”

 

 

18.

Initial Air

“18: CW PUMP.

CWP on for 2

Clamp CWT vent

 

Pressurization with

CLAMP&PSI-M”

seconds. Verify

tube, add pressure

 

Water Pump,

“MODULE: CWP, C-

>0.25 psi

gauge. Press Right

 

Pressure transducer

PCB, LEAK”

 

Button when ready.

 

 

R LED blinks

 

 

19.

Vent Valve opening

“19: VV OPEN LO-PSI”

Vent Valve open for

Auto Continue if

 

under low pressure

“MODULE: CWT”

2 seconds – Verify

OK

 

 

 

<0.1 psi

 

20.

Full HWT air

“20: BREW PUMP

Runs Brew Pump

Auto Continue if

 

Pressurization with

7PSI?”

until 7 psi. Checks

OK

 

Brew Pump.

“MODULE: HWT,

pressure drop below

 

 

Pressure transducer

LEAKS”

.21 psi (7 psi - 3%)

 

 

calibration

 

over 5s. If pass,

 

21.

Half CWT

“21: VV OPEN HI-PSI”

Opens VV.

Auto Continue if

 

Pressurization by

“MODULE: CWT”

(tanks equalize)

OK

 

sharing;

 

Wait 5 seconds –

 

 

Vent Tubes

 

check for pressure 2-

 

 

Vent Valve opening

 

5 psi.

 

 

under full over

 

 

 

 

pressure

 

 

 

22.

CWT, Vent Tubes

“22: CWT LEAK”

Checks pressure drop

Auto Continue if

 

Leaks

“MODULE: CWT,

below .21 psi (4 psi -

OK

 

 

LEAKS”

5%) over 5 seconds

 

23.

HW Dispense valve

“23: HWD VALVE”

Open VV. Open

Auto Continue if

 

 

“MODULE: BR-HEAD”

HWDV. Verify

OK

 

 

 

HWT <0.1 psi after 2

 

 

 

 

seconds

 

24.

Brew tank

“24: BREW TEMP”

 

Auto Cont. if OK

 

Thermistor @

“MODULE: HWT”

 

 

 

ambient temperature

 

 

 

25.

Pre-heat tank

“25: PREHEAT TEMP”

 

Auto Cont. if OK

 

Thermistor @

” MODULE: HWT”

 

 

 

ambient temperature

 

 

 

26.

Heaters off

“26: HEATER LOW

 

Press Right Button

 

 

AMP?”

 

if less than 1 amp

 

 

“MODULE: POWER”

 

 

 

 

R LED blinks

 

 

 

 

B3000 SERVICE MANUAL

 

 

 

60-200807-000, REV C

 

90