27.

HW Dispense valve

“27: HWD VALVE”

Open VV. Open

Auto Continue if

 

 

“MODULE: BR-HEAD”

HWDV. Verify

OK

 

 

 

HWT <0.1 psi after 2

 

 

 

 

seconds

 

28.

Transmit and receive

“29: VEND I/F

 

Auto Continue if

 

a “1” and “0”

LOOPBACK”

 

OK

 

through the coin IF

“MODULE: M-PCB,

 

 

 

 

PWR-PANEL”

 

 

29.

Done

“30: PASS, !!!!”

Power off

Stop

 

 

“DONE”

 

 

Test 24 pressurizes the entire hot water part of the brewer, thus checking for leaks in:

 

• All vent line components from the tank through the VV. Tested open in 25

The HWT

All fill line components from the HWT through the CWP. Tested open in 22

All brew line components.

Not tested open

Test 25 pressurizes the cold water part of the brewer, thus checking for leaks in:

The vent line from the CWT to the bin.

Not tested open

The CWT

 

The tube from the CWT to the CWP.

Tested open in 22

The inlet valve and high pressure tubing. (to 4 psi)

Tested open in 28

Some components are not tested. The functionality was tested by manufacturing.

Float valve

CWT and HWT drains open

Dispense line from Dispense Valve to Mug

TCOs opening and TCO sensors

Conductive probes and power

Inlet Valve

Hi-Pot

The coin IF loopback plug shorts the transmit to receive pin (RJ11 pins 3 and 4).

B3000 SERVICE MANUAL

 

60-200807-000, REV C

88