AlphaServer 8400

Step 8—Networks and Communications (continued

LAN Communications Controllers EISA based

Requires DWLPB-AA and KFE70-AA, EISA bridge module set.

See EISA Bus IRQ Address Table.

DNSES-AA

Synchronous Communications Controller (uses one EISA slot). DIGITAL UNIX supports two per

 

EISA, maximum two per system. OpenVMS supports one per EISA, maximum one per system.

 

Requires a BC19x cable.

BC19B-02

EIA-422-A/V.11 adapter cable, can be extended with BC55D-33

BC19D-02

EIA-232-D/V.24 adapter cable, can be extended with BC22F-xx

BC19E-02

EIA-423-A/V.10 adapter cable, can be extended with BC55D-33

BC19F-02

V.35 adapter cable, can be extended with BC19L-25

DW300-AA

Token Ring Adapter (uses one EISA slot). DIGITAL UNIX and OpenVMS V6.2 plus remedial

 

stream TIMA kit (TPPR 614) support one per EISA, maximum one per system. Requires BN26M

 

cable.

BN26M-xx

802.5/Token Ring twisted-pair cable; 8-pin MP to 8-pin MP, screened, EIA/TIA Category 5 cable.

CXI01-AA

Digiboard Asynchronous Xem/ISA Multiport Serial Card with 16 RJ45 PORTS/Xem Port (uses

 

one EISA slot). DIGITAL UNIX only, supports one per EISA, maximum one CXI01-AA/AD per

 

system.

CXI01-AB

Digiboard PORTS/Xem, 16 RJ45 Port Concentrator—mounts separately from PCI bus.

 

Maximum of three CXI01-AB can be attached to CXI01-AA, provides up to 48 additional ports.

 

DIGITAL UNIX only.

CXI01-AD

Digiboard Asynchronous EPC/X Multiport Serial Card with 16 RJ45 Port EPC/CON-16

 

Concentrator (uses one EISA slot). DIGITAL UNIX one per EISA, maximum one CXI01-AA/AD

 

per system. DIGITAL UNIX only.

CXI01-AE

Digiboard EPC/CON-16 Concentrator mounts separate from PCI bus. Maximum three CXI01-AE

 

can be attached to the CXI01-AD provides up to 48 additional ports. DIGITAL UNIX only.

CXI01-AC

Digiboard RJ45 to DB25 Male Converter

CXI01-AF

Digiboard RJ45 to DECMJ11 Adapter—8 per package

LAN Communications Controllers XMI based

DEMNA-M

802.3/Ethernet controller XMI-to-Ethernet adapter, (uses one XMI slot). OpenVMS supports four

 

per XMI, maximum six per system. DIGITAL UNIX supports six per XMI, maximum eight per

 

system.

CK-DEMNA-KN

DEMNA cabinet kit, required with DEMNA-M

DEMFA-AA

DEC FDDIcontroller 400 XMI-to-FDDI adapter, Single attachment station with fiber MIC

 

connector; (uses one XMI slot). OpenVMS supports four per XMI, maximum four per system.

 

DIGITAL UNIX supports seven per XMI, maximum eight per system.

Local and Wide Area Communications Servers

Each communications server requires 802.3/Ethernet connection. Depending on the server selected, either ThinWire BNC- type connection (e.g., BC16M cable) or thick wire 15-pin AUI transceiver cable (e.g., BNE3x) is required. Additional items also required—see Network Products Guide for ordering information.

Network Connectivity Products

See Network Products Guide for details.

Alpha Servers 3.219