AlphaServer 8400 Power Configuration Table
3.226 Alpha Servers
AlphaServer 8400 EPU (Equivalent Power Units) Power Configuration Table
Second power regulator may be needed to supply additional 48V power to the system.
Mixing of three-phase and single-phase power regulators in system configuration is not allowed.
Use chart to determine need for second power regulator.
If EPU is greater than 80, order second power regulator (three-phase regulator H7263-AC/AD) or H7263-AA/AB if
BBU is required).
EPU must not exceed 180.
Options
EPU Values
System
Cabinet
Options Quantity
Total
EPU
(Qty times
EPU)
EPU Values
Expansion
Cabinet
Options Quantity
Total
EPU
(Qty times
EPU)
Base system includes power regulator, CPU module,
system I/O module, memory module 30 1 30
I/O expansion cabinet (H9F00-BA/BB/BC) includes
one power regulator 10
Additional 5/300 CPU modules 751P1-AX, 751P2-AX 11
Additional 5/300 CPU modules 752P1-AX, 752P2-AX 13
Additional 5/350 CPU modules 753P1-AX, 753P2-AX 12
Additional 5/350 CPU modules 754P1-AX, 754P2-AX 14
Additional dual 5/440 CPU modules—756P1-AX, 756P2-AX 8
KFTIA-AA System I/O module 4
KFTHA-AA System I/O module 3
MS7CC-BA 128 MB memory 5
MS7CC-CA 256 MB memory 5
MS7CC-DA 512 MB memory 5
MS7CC-EA 1 GB memory 5
MS7CC-FA 2 GB memory 5
MS7CC-GA 4 GB memory 5
Add PCI options
DWLPB-AA/AB/BA/BB 1
KZPSA-BB 1
KZPSC-AA/BA, KZPAC-AA/CA/CB 1
DE435-AA, DE450-AA, DE500-XA, DE500-AA 1
DEFPA-AB/DB/UB/MB 1
KFE70-AA 1
Add EISA options
DNSES-AA 1
DW300-AA 1
CXI01-AA/AD 1
Add XMI options
DWLMA XMI plug-in unit 4
KZMSA-AB XMI SCSI controller 3
KFMSB-AA DSSI disk/tape adapter 3
CIXCD-AC XMI CI controller 4
DEMNA-M XMI Ethernet controller 3
DEMFA-AA XMI FDDI adapter 5
Disk and Tape options
8-bit SCSI disk drives 1
16-bit SCSI disk drives 1
TLZ07, TLZ09, TLZ9L, TLZ15-VA SCSI tape drive 1
TZ86, TZ87, TZ88 -VA SCSI tape drive 3
DWZZA-VA/DWZZB-VW SCSI signal converter 0
Total
Note: Depending on configuration, system offers integral UPS capability that supports all in-cabinet components for at
least 11 minutes. If UPS support is required for external devices, e.g., console terminals, terminal servers, printers,
and modems, a universal UPS can be ordered separately.