AlphaServer 8400 Power Configuration Table

AlphaServer 8400 EPU (Equivalent Power Units) Power Configuration Table

Second power regulator may be needed to supply additional 48V power to the system.

Mixing of three-phase and single-phase power regulators in system configuration is not allowed. Use chart to determine need for second power regulator.

If EPU is greater than 80, order second power regulator (three-phase regulator H7263-AC/AD) or H7263-AA/AB if BBU is required).

EPU must not exceed 180.

 

 

EPU Values

 

Total

EPU Values

 

Total

 

 

System

 

EPU

Expansion

 

EPU

Options

 

Cabinet

 

(Qty times

Cabinet

 

(Qty times

 

Options

Quantity

EPU)

Options

Quantity

EPU)

 

 

 

 

 

 

 

Base system includes power regulator, CPU module,

30

1

30

 

 

 

system I/O module, memory module

 

 

 

 

 

 

I/O expansion cabinet (H9F00-BA/BB/BC) includes

 

 

 

 

1

0

one power regulator

 

 

 

 

 

 

 

Additional 5/300 CPU modules

751P1-AX, 751P2-AX

11

 

 

 

 

 

Additional 5/300 CPU modules

752P1-AX, 752P2-AX

13

 

 

 

 

 

Additional 5/350 CPU modules

753P1-AX, 753P2-AX

12

 

 

 

 

 

Additional 5/350 CPU modules￿754P1-AX, 754P2-AX

14

 

 

 

 

 

Additional dual 5/440 CPU modules—756P1-AX, 756P2-AX

8

 

 

 

 

 

KFTIA-AA System I/O module

 

4

 

 

 

 

 

KFTHA-AA System I/O module

 

3

 

 

 

 

 

MS7CC-BA 128 MB memory

 

5

 

 

 

 

 

MS7CC-CA 256 MB memory

 

5

 

 

 

 

 

MS7CC-DA 512 MB memory

 

5

 

 

 

 

 

MS7CC-EA 1 GB memory

 

5

 

 

 

 

 

MS7CC-FA 2 GB memory

 

5

 

 

 

 

 

MS7CC-GA 4 GB memory

 

5

 

 

 

 

 

Add PCI options

 

 

 

 

 

 

 

DWLPB-AA/AB/BA/BB

 

1

 

 

 

 

 

KZPSA-BB

 

1

 

 

 

 

 

KZPSC-AA/BA, KZPAC-AA/CA/CB

1

 

 

 

 

 

DE435-AA, DE450-AA, DE500-XA, DE500-AA

1

 

 

 

 

 

DEFPA-AB/DB/UB/MB

 

1

 

 

 

 

 

KFE70-AA

 

1

 

 

 

 

 

Add EISA options

 

 

 

 

 

 

 

DNSES-AA

 

1

 

 

 

 

 

DW300-AA

 

1

 

 

 

 

 

CXI01-AA/AD

 

1

 

 

 

 

 

Add XMI options

 

 

 

 

 

 

 

DWLMA XMI plug-in unit

 

4

 

 

 

 

 

KZMSA-AB XMI SCSI controller

3

 

 

 

 

 

KFMSB-AA DSSI disk/tape adapter

3

 

 

 

 

 

CIXCD-AC XMI CI controller

 

4

 

 

 

 

 

DEMNA-M XMI Ethernet controller

3

 

 

 

 

 

DEMFA-AA XMI FDDI adapter

 

5

 

 

 

 

 

Disk and Tape options

 

 

 

 

 

 

 

8-bit SCSI disk drives

 

1

 

 

 

 

 

16-bit SCSI disk drives

 

1

 

 

 

 

 

TLZ07, TLZ09, TLZ9L, TLZ15-VA SCSI tape drive

1

 

 

 

 

 

TZ86, TZ87, TZ88 -VA SCSI tape drive

3

 

 

 

 

 

DWZZA-VA/DWZZB-VW SCSI signal converter

0

 

 

 

 

 

Total

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Depending on configuration, system offers integral UPS capability that supports all in-cabinet components for at least 11 minutes. If UPS support is required for external devices, e.g., console terminals, terminal servers, printers, and modems, a universal UPS can be ordered separately.

3.226 Alpha Servers

Page 21
Image 21
Key Digital 8400 warranty Add Eisa options