I n s t a l l a t i o n

Pull the AC Quick-Connect wire harness through the center hole in the mounting bracket and secure the bracket, making sure that the mounting screws are positioned in the small ends of the keyholes before tightening (Image 4B).

Plug the AC Quick-Connect wire harness into the back of the alarm (Image 5), making sure that the locks on the connector snap into place. Push the excess wire back into the electrical box through the hole in the center of the mounting plate.

IMAGE 5 ATTACHING THE AC QUICK-CONNECT WIRE HARNESS

Install the alarm on the mounting plate and rotate the alarm in the direction of the “ON” arrow on the cover until the alarm ratchets into place (Image 4D). This ratcheting function allows for aesthetic alignment. Note: The alarm will attach to the mounting plate in 4 positions (every 90 degrees). When wall mounting, make sure the battery door is at the bottom of the unit (Image 4C).

Battery

This unit will not function without a properly installed battery, and is equipped with a battery lockout feature which prevents the battery door from closing if a battery is not installed correctly. See Maintenance section for additional information concerning battery installation.

For initial installation a pre-installed 9 V battery is included with a battery pull tab that allows for easy connection. Simply pull the tab out, and the battery backup is connected! See Maintenance for additional information concerning battery installation.

Pull the Battery Pull Tab (yellow tab protruding from the unit) completely out of the unit. This will automatically connect the battery.

O p e r a t i o n

Testing

Test the unit to ensure proper operation by pressing the Test button. (All interconnected, battery backed-up alarms, should respond).

CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arms-length away from the unit when testing.

Turn on the AC power. The green Power On Indicator should be lit when the alarm is operating from AC power.

C o n f i rm unit operation by pressing the Test button again.

The smoke alarm is operating once AC power is applied, a f resh battery is installed and testing is complete. When the smoke alarm ionization sensor chamber senses products of combustion, the horn will sound a loud (85db) alarm until the sensing chamber is cleared of smoke particles.

CONTRACTOR’S NOTE: Only remove the battery pull-tab once AC is permanently applied. Unit will chirp if AC is applied and the pull-tab is still present.

11

12

Page 7
Image 7
Kidde 1276CA manual E r a t i o n, Battery, Testing

1276CA specifications

The Kidde 1276CA is a highly regarded smoke and carbon monoxide (CO) detector designed to enhance safety and provide peace of mind for your home. This advanced device combines state-of-the-art technology with user-friendly features, making it an essential addition to any household.

One of the standout features of the Kidde 1276CA is its dual-sensor technology. This model incorporates both ionization and photoelectric sensing technologies, enabling it to detect a wide range of fire types effectively. Ionization sensors are particularly responsive to flaming fires, while photoelectric sensors excel in detecting smoldering fires. The combination of these two sensing methods allows for faster response times and increased reliability in various fire scenarios.

The Kidde 1276CA is also equipped with a sealed lithium battery, which boasts a lifespan of up to 10 years. This eliminates the need for frequent battery replacements, providing both convenience and consistent performance over an extended period. The sealed battery design ensures that users never have to worry about battery maintenance, as the unit will inform you when the end of its operational life is approaching.

In addition to its smoke detection capabilities, the Kidde 1276CA features an integrated carbon monoxide sensor. Carbon monoxide is a silent and deadly gas that can result from malfunctioning appliances or improper ventilation. This detector can sense dangerous levels of CO and alert occupants with a loud alarm, safeguarding families from potential poisoning.

Furthermore, the Kidde 1276CA comes with a convenient test and reset button, allowing users to regularly check the unit's functionality easily. The easy-to-read LED indicators provide visual confirmation of the unit's operational status, while a low battery warning and end-of-life reminder ensure that users stay informed about their detector's condition.

Installation is straightforward, as the Kidde 1276CA can be mounted on walls or ceilings. Its compact and modern design blends seamlessly with any home decor. With an emphasis on user safety, this device meets all the necessary regulatory standards and certifications, making it a reliable choice for residential fire safety.

In conclusion, the Kidde 1276CA is a comprehensive smoke and carbon monoxide detector that combines advanced sensing technology, user-friendly features, and reliable performance. It offers peace of mind to families by effectively detecting potential hazards, simplifying maintenance, and ensuring comprehensive protection against both smoke and carbon monoxide risks. Investing in the Kidde 1276CA is a proactive step towards a safer living environment.