7.Model KN-COP-IC (with digital display) Operating Characteristics

The following table illustrates the possible digital displays, describes the audible alarm patterns, and the recommended actions to take.

Operating and Alarm Characteristics

LED Display Shows

Alarm Sound

Unit Status

Recommendation

 

 

 

 

Brief “888” along

4 quick beeps,

Self checking when

None – CO has not

with any number

5 seconds

AC powered (Test

been detected.

between 100 and 300.

silence,

button was pressed

Numbers shown for

Red LED flashes with beeps.

repeated once

or unit was first

test purposes only

Green and amber LED’s on.

 

powered)

 

 

 

 

 

Steady “0”

None

Normal AC

None

Green LED

 

operation (sensing

 

constantly on.

 

no CO) and with a

 

 

 

good battery

 

 

 

 

 

“Lb” flashes

One quick

AC powered and

Install or replace 9V

alternately with

beep every

low or missing

battery.

any number.

15 seconds

battery

 

Red LED flashes

 

 

 

every 15 seconds.

 

 

 

 

 

 

 

A steady display of

4 quick beeps,

Alarm condition.

Refer to “What to do

CO concentration

5 seconds

Dangerous

When the Alarm

from 30-999. Red

silence,

concentrations of

Sounds” (inside front

LED flashes with beeps. Amber

repeating

CO detected

cover)

LED shows initiating alarm.

 

 

 

 

 

 

 

Steady “CO”

4 quick beeps,

Interconnected CO

Refer to “What to do

Red LED flashes with

5 seconds

alarm warning of a

When the Alarm

beeps. Amber LED

silence,

CO condition

Sounds” (inside front

shows initiating alarm

repeating

 

cover)

 

 

 

 

“FirE”

3 long beeps,

Interconnected

Evacuate by your

Red LED flashes

1 second

smoke alarm

escape plan

with beeps

silence,

warning of a

 

 

repeating

smoke/fire condition

 

 

 

 

 

Steady “Err”

One quick

Unit malfunction

Replace battery.

Red LED flashes every

beep every

 

If “Err” continues,

30 seconds

30 seconds

 

unit has malfunc-

 

 

 

tioned. Replace

 

 

 

immediately. Unit will

 

 

 

not respond CO

 

 

 

 

No display alternating

4 quick beeps,

Alarm condition

Refer to “What to do

with display of CO

5 seconds

powered on battery

When the Alarm

concentration every 60

silence,

backup. Dangerous

Sounds” (inside front

seconds. Red LED

repeating

concentrations of

cover).

flashes with beeps

every 60 secs

CO detected

Replace battery

 

 

 

 

No display alternating

None

Normal operation

Verify AC power is

with “0” every 60

 

after first 4 minutes

restored as soon as

seconds.

 

of 9 V battery

possible to conserve

Green LED flashes

 

operation. Unit

battery.

every 7 seconds

 

monitoring for CO

Replace battery

7.Model KN-COP-IC (with digital display) Operating Characteristics

Peak Level Memory (model KN-COP-IC only)

When the Peak Level button is pressed and held, the display shows the highest CO reading taken by the CO alarm since its last reset or power up. The Peak Level display feature will display levels between 11-999 PPM. Although the Peak Level feature will display levels below 30 PPM, these levels will not result in an alarm no matter how long the device is exposed to these levels. The Peak Level feature is helpful in identifying if you have had a CO reading since resetting the alarm.

Concentrations of CO between 1 and 30 PPM can often occur in nor- mal, everyday conditions. Concentrations of CO below 30 PPM may be an indication of a transient condition that may appear today and never reappear. Some CO conditions may start out as low level leaks but could develop into CO concentrations that may become harmful.

Peak Level Memory Reset

Press the Peak Level button; with the button still pressed, press the Test/Reset button for two seconds and release. The number on the dis- play will turn to “0”, the memory will be cleared and the alarm will begin monitoring for CO. The Peak Level memory is also reset when the unit loses power.

8. Maintenance

NOTE: This unit is sealed. The cover is not removable.

Due to the loudness of the alarm, we suggest that you place your fingers over the sounder opening while testing your alarm.

CAUTION: Continuous exposure to the high sound level of this alarm over an extended period of time may cause hearing loss.

Testing

To test the alarm, press the Test/Reset button. If the unit is operating properly, you should hear 4 quick beeps – followed by 5 seconds of silence – followed by 4 quick beeps. (For model KN-COP-IC with digi- tal display: The display will show three “eights” and then show a num- ber – usually around 200). The red LED will flash along with the beeps and the amber LED will illuminate. Within several seconds the unit will return to monitor for CO.

If interconnected to Kidde smoke alarms, pressing the Test/Reset button on the CO alarm will have no effect on the smoke alarms. The smoke

Page 10
Image 10
Kidde kn-cop-ic, kn-cobic manual Maintenance, Peak Level Memory model KN-COP-IC only, Peak Level Memory Reset, Testing

kn-cop-ic, kn-cobic specifications

The Kidde KN-COP-IC and KN-COB-IC are advanced carbon monoxide (CO) and explosive gas detectors designed to enhance home safety through state-of-the-art technology. These devices serve as a crucial line of defense against the dangers posed by carbon monoxide, a colorless, odorless gas that can lead to serious health risks or even fatality if undetected.

One of the main features of the Kidde KN-COP-IC is its electrochemical CO sensor, which provides accurate readings while also minimizing the chances of false alarms. This sensor technology allows the device to detect the presence of carbon monoxide at lower concentrations, making it effective in a variety of environments, including homes, garages, and other enclosed spaces. The KN-COB-IC model, focusing on explosive gases, utilizes a sophisticated catalytic bead sensor that can precisely identify the presence of combustible gases, such as natural gas and propane.

Both models are equipped with a digital display that provides real-time readings, making it easy for users to monitor CO levels and other hazardous gases present in their environment. The KN-COP-IC offers a peak level memory feature, which stores the highest levels of CO detected since the last reset. This helps users understand previous exposure levels, potentially informing safety and health decisions.

In terms of installation and usability, the Kidde detectors come with a battery backup to ensure continuous operation, even during power outages. They are designed for easy mounting, whether on walls or ceilings, and are compact enough to blend seamlessly into home decor. Furthermore, the integrated test/silence button allows users to check the functionality of the alarm and silence it during false alarms or maintenance checks.

Both the KN-COP-IC and KN-COB-IC models meet stringent safety standards and certifications, ensuring they provide reliable protection. Regular maintenance is simplified with clear instructions included in the user manual, along with the recommendation to replace the units after a specified period, usually around 7 years for CO detectors.

In conclusion, the Kidde KN-COP-IC and KN-COB-IC are essential tools in modern home safety. With their advanced sensor technology, user-friendly features, and reliable performance, these detectors not only safeguard families from carbon monoxide and explosive gases but also promote peace of mind in everyday living. By investing in these reliable detectors, homeowners can ensure the safety and well-being of their loved ones.