Kidde KN-COPE-I manual Sloped Ceiling Installation, Mobile Homes

Models: KN-COPE-I

1 35
Download 35 pages 53.36 Kb
Page 14
Image 14
Sloped Ceiling Installation:

Operating and Installation Instructions

Sloped Ceiling Installation:

The following information is from the National Fire Protection Association and is listed in Fire Code 72. Install Smoke Alarms on sloped, peaked or cathedral ceilings at, or within 3 ft (0.9m) of the highest point (measured horizon- tally). NFPA 72 states “Smoke alarms in rooms with ceiling slopes greater than 1 ft to 8 ft (.3 m-2.4 m) horizontally shall be located on the high side of the room”.

NFPA 72 states “A row of alarms shall be spaced and locat- ed within 3 ft (0.9 m) of the peak of the ceiling measured horizontally” (see figure 2).

FIGURE 2

Mobile Homes:

Modern mobile homes have been designed and built to be energy efficient. Install Smoke/CO alarms as recommended previously (refer to Recommended Installation Instructions and figure 1). In older mobile homes that are not well insu- lated, extreme heat or cold can be transferred from the out- side to the inside through poorly insulated walls and roof. This may cause a thermal barrier, which can prevent smoke from reaching an alarm mounted on the ceiling. In such mobile homes install your Smoke/CO Alarm on an inside wall with the top edge of the alarm at a minimum of 4 inches (10cm) and a maximum of 12 inches (30.5cm) below the ceiling (See figure 1). If you are not sure about the insu- lation in your mobile home, or if you notice that the outer walls and ceiling are either hot or cold, install your alarm on an inside wall ONLY!

THIS EQUIPMENT SHOULD BE INSTALLED IN ACCOR- DANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIA- TION’S STANDARD 72 (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269).

9

Page 14
Image 14
Kidde KN-COPE-I manual Sloped Ceiling Installation, Mobile Homes, Operating and Installation Instructions