Electrical requirements
Electrical Shock Hazard
l Electrical ground is required on this appliance.
lDo Not ground to a gas pipe.
l Do Not have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in an electrical shock.
l Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.
Failure to follow these instructions could result in serious injury or death.
If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate.
IMPORTANT:
Save Installation Instructions for the local electrical inspector’s use.
This appliance must be connected to the proper electrical voltage and
frequency as specified on the serial/rating plate located behind the oven door (double oven models - upper oven) on the front frame. A fuse is required in both sides of the line. A time-delay fuse is recommended. Use the voltage and kilowatt rating given on the serial/rating plate to select the proper fuse size from the chart.
Electrical connection
Electrical Shock Hazard
l Electrical ground is required on this appliance.
l Do Not connect to the electrical supply until appliance is permanently grounded.
l Disconnect power to the junction box before making the electrical connection.
l This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.
Failure to do so could result in a fire, personal injury or electrical shock.
This appliance is manufactured with white (neutral) power supply wire and a cabinet- connected green grounding wire twisted together.
Connect the appliance cable to the junction box through the U.L.-listed conduit connector. Complete electrical connection according to local codes and ordinances.
A. Where local codes permit...
connecting the cabinet-grounding conductor to the neutral (white) junction box wire:
Cable from
C. If connecting to a four-
wire electrical system...
Do Not connect the cabinet-grounding conductor to the neutral (white) junction box
iom
White
| wlree | conduit |
| Figure 3 |
| connector |
1.Disconnect the power supply.
2.Separate the green (or bare) and white appliance cable wires.
3.Connect the white appliance cable wire to the neutral (white) wire in the junction box.
4.Connect the two black wires together; then the two red wires together. See Figure 3.
5.Connect the green appliance cable wire to the green grounding wire in the junction box.
Now start...
with oven in kitchen.
Remove shipping materials, tape, and protective film from oven. Do Not
remove’shipping base at this time.
121Remove the racks and other parts
. from inside the oven.
Fuse Requirements:
120/208 | 6.2 | 30 | a | 6 | 6 | | Figure 1 | | conduit |
| 6.2 to 8x3 | 40 | a | 6 | 4 | | Cable | connector |
| | | | | | | | from | oven |
[I | | | | | | | l.Di;nnect~~~~~ | | . _ ,- . |
| | | | | | | 2. Remove the terminal block cover. |
1 | | | | | | 1 | 3. Connect together 3 wires: green and white |
your local | | | | | appliance cable wires and the neutral (whrte) |
+ Check | codes | and | ordinances. | | |
| | wire in junction | box. | |
| | | | | | | |
4. Connect the two black wires together; then the two red wires together. See Figure 1.
l Use both hands to remove oven doors. l Grasp only the sides of oven doors.
l Do Not use handle or any portion of the trim for lifting.
l Because of the weight and size of the single or double oven, two or more people are needed to move and safely install the oven.
Failure to properly grasp the oven doors or to lift ovens properly could result in damage to the product or personal injury.
OVEN MUST BE CONNECTED WITH
IBI n SOLID COPPER WIRE ONLY.
Wire sizes and connections must El . conform to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition** and all local codes and ordinances. Wires sizes and connections must conform with the rating of the appliance.
Copies of the standards listed may be obtained from:
B. Where local codes Do Not
permit...
connecting the cabinet-grounding conductor to the neutral (white) junction box wire:
Cable from
“National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
This appliance should be connected IDI . directly to the fused disconnect (or circuit breaker box) through flexible, armored or non-metallic sheathed, copper cable (with
Cable conduit from oven connector
Selfcleaning ovens: Insert a nail (or equivalent, 5/32” diameter item) into the hole in each of the hinges. Close the door as far as possible. Lift the oven door off of the hinges. Set aside.
Non-self cleaning ovens: Open the oven door
grounding wire). The flexible armored cable from the appliance should be connected directly to the junction box.
E-ILocate the junction box to allow as
. much slack in the cable as possible between the junction box and the appliance so that the oven can be moved if servicing is ever necessary. Do Not cut the conduit.
El A U.L.-listed conduit connector must
. be provided at the junction box.
IGIA wiring diagram is included in the n Tech Sheet. The Tech Sheet is
located behind the air grille.
Ungrounded Neutral
1.Disconnect power supply.
2.Separate the green and white appliance cable wires.
3.Connect the white appliance cable wire to the neutral (white) wire in the junction box.
4.Connect the two black wires together; then the two red wires together. See Figure 2.
5.Connect the green or bare grounding wire from the appliance cable to a grounded wire in the junction box.
to the broil “stop”position and lift the door upwards to remove. Set oven door aside.
Property Damage
Before moving oven across floor, check that oven is on shipping base or slide single or double oven onto cardboard or hardboard.
Failure to follow these instructions may result in damage to floor covering.
141Turn power supply off. Move oven close
. to final position. Remove and discard shipping base. Feed appliance cable through the opening in cabinet. Make electrical connection. See “Electrical requirements” and “Electrical connection” sections, Panel B.