7. Press on handle in front of filters to release filters from range hood canopy. Remove filters and set aside.
8. Remove the terminal box cover from the canopy hood. Remove the power supply cable knockout using a
WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
adjustment screw
9. Align the “T” area of the canopy hood slots with the lower bracket flanges. Push hood toward wall. Gently lower the hood making sure the lower bracket flanges are fully inserted into the slots. Check that the hood is secure on the lower bracket. Feed enough power supply cable through conduit connector to make electrical connections.
10. Level the hood and adjust hood height by turning the adjusting screws.
Electrical connection
WARNING
Electrical Shock Hazard
Disconnect power before making electrical connections.
Connect ground wire to green ground screw in terminal box.
Failure to do so can result in death or electrical shock.
11. Make electrical connection:
Connect the power supply cable to hood terminal box through the U.L.- or
Connect the white wire of the power supply cable with the white lead in the hood using a
Connect the power supply green (green and yellow) ground wire under the green, ground screw.
Tighten conduit connector screws.
Replace the terminal box cover.
Install chimney sections
12. If roof or wall cap does not have a damper, attach damper to exhaust opening on top of the canopy using two
vent |
upper
bracket
upper chimney
13. Carefully fit the upper chimney rear flanges behind the upper and middle bracket.
middle | vent |
bracket |
|
lower chimney | upper chimney |
14.Carefully fit the lower chimney rear flanges behind the upper chimney flanges on the middle bracket and behind the lower bracket.
upper
chimney screws
screws
lower chimney
15. When upper and lower chimney sections are in final position, attach the top of the upper chimney and the bottom of the lower chimney to the top and bottom brackets.