16

Determine vent length and elbows needed for best

drying performance

Use the Vent system chart below to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified in
the Vent system chart. Exhaust systems longer than those
specified will:
Shorten the life of the dryer.
Reduce performance, resulting in longer drying times and
increased energy usage.
The Vent system chart provides venting requirements that will
help to achieve the best drying performance.

Vent system chart

NOTE: Side and bottom exhaust installations have a 90º turn
inside the dryer. To determine maximum exhaust length, add one
90º turn to the chart.
InstallVent System
1. Install exhaust hood. Use caulking compound to seal exterior
wall opening around exhaust hood.
2. Connect vent to exhaust hood. Vent must fit inside exhaust
hood. Secure vent to exhaust hood with 4" (10.2 cm) clamp.
3. Run vent to dryer location. Use the straightest path possible.
See Determine vent path in Plan Vent System. Avoid 90º
turns. Use clamps to seal all joints. Do not use duct tape,
screws or other fastening devices that extend into the interior
of the vent to secure vent.
InstallLeveling Legs
1. To protect the floor, use a large flat piece of cardboard from
the dryer carton. Place cardboard under the entire back edge
of the dryer.
2. Firmly grasp the body of the dryer (not the console panel).
Gently lay the dryer on the cardboard. See illustration.
3. Examine the leveling legs. Find the diamond marking.
4. Screw the legs into the leg holes by hand. Use a wrench to
finish turning the legs until the diamond marking is no longer
visible.
5. Place a carton corner post from dryer packaging under each
of the 2 dryer back corners. Stand the dryer up. Slide the
dryer on the corner posts until it is close to its final location.
Leave enough room to connect the exhaust vent.
ConnectVent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in
dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final position. Do not crush or kink vent.
3. (On gas models) Check to be sure there are no kinks in the
flexible gas line.
4. Once the exhaust vent connection is made, remove the
corner posts and cardboard.
Number of
90º turns
or elbows
Type o f
vent Box or
louvered
hoods
Angled
hoods
0 Rigid metal
Flexible metal 64 ft (20 m)
36 ft (11 m) 58 ft (17.7 m)
28 ft (8.5 m)
1 Rigid metal
Flexible metal 54 ft (16.5 m)
31 ft (9.4 m) 48 ft (14.6 m)
23 ft (7 m)
2 Rigid metal
Flexible metal 44 ft (13.4 m)
27 ft (8.2 m) 38 ft (11.6 m)
19 ft (5.8 m)
3 Rigid metal
Flexible metal 35 ft (10.7 m)
25 ft (7.6 m) 29 ft (8.8 m)
17 ft (5.2 m)
4 Rigid metal
Flexible metal 27 ft (8.2 m)
23 ft (7 m) 21 ft (6.4 m)
15 ft (4.6 m)
WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.

Failure to do so can result in back or other injury.