Recommended installation spacing for recessed or closet installation, with or without a pedestal
■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
Mobile home installations require:
■ Metal exhaust system hardware, which is available for |
purchase from your dealer. |
■ Mobile home Installation Kit Part Number 346764. See “Tools |
and Parts” section for ordering information. |
■ Special provisions must be made in mobile homes to |
introduce outside air into the dryer. The opening (such as a |
nearby window) should be at least twice as large as the dryer |
1" | 27" | 1" |
(2.5 cm) | (68.6 cm) | (2.5 cm) |
| A |
|
| 3"* |
| (7.6 cm) |
48 in.2* |
|
(310 cm2) |
|
24 in.2* | 3"* |
(155 cm2) | |
| (7.6 cm) |
| 1" |
| 33" |
|
| 5" |
|
|
|
|
|
| |||
(2.5 cm) |
| (83.8 cm) (12.7 cm) |
BC
exhaust opening. |
Electrical Requirements
WARNING
A. Front view
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Recommended installation spacing for cabinet installation, with or without a pedestal
■For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.
|
|
| 7"* (17.8 cm) | 7"* (17.8 cm) | |
1" | 27" | 1" | 5" | 33" | 1" |
(2.5 cm) (68.6 cm) (2.5 cm) (12.7 cm) (88.8 cm) (2.5 cm) | |||||
| A |
|
| B | C |
A. Front view
B. Side view
C. Cabinet with vents
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
■120 Volt, 60 Hz., AC only, 15- or
GROUNDING INSTRUCTIONS
■For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.