Connect Vent
1.Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (10.2 cm) clamp.
2.Move dryer into its final location. Do not crush or kink vent.
3.Check that there are no kinks in the flexible gas line.
Level Dryer
All four dryer feet were preset to the same height at the factory.
1.Using a ⁹⁄₁₆" (14 mm)
2.Slide the dryer to its final location.
3.Check the levelness of the dryer. Check levelness first side to side, then front to back.
4.If the dryer is not level, move the dryer slightly away from the wall and first prop the front with a wood block and adjust the feet as necessary; then prop the back and adjust feet as necessary. Repeat this step until dryer is level.
5.After the dryer is level, use a ⁹⁄₁₆" (14 mm)
Complete Installation
1.Check that all parts are now installed. If there is an extra part, go back through the steps to see which step was skipped.
2.Check that you have all of your tools.
3.Check the dryer’s final location. Be sure the vent is not crushed or kinked.
4.Check that the dryer is level. See “Level Dryer.”
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
5.Plug into a grounded 3 prong outlet. Turn on power.
6.Remove any protective film or tape remaining on the dryer.
7.Dispose of/recycle all packaging materials.
8.Set the decorative mat in place on top of the dryer, if desired. NOTE: Check that the top of the dryer and the bottom of the mat are clean.
9.Read “Dryer Use.”
10.Wipe the dryer drum interior thoroughly with a damp cloth to remove any dust.
11.Select a Timed Dry heated cycle, and start the dryer. Do not select the Air Only Temperature setting.
If the dryer will not start, check the following:
■Dryer is plugged into a grounded 3 prong outlet.
■Electrical supply is connected.
■Household fuse is intact and tight, or circuit breaker has not tripped.
■Dryer door is closed.
12.When the dryer has been running for 5 minutes, open the dryer door and feel for heat. If you feel heat, cancel cycle and close door. If you do not feel heat, turn off the dryer and check that the gas supply line shutoff valve is open.
■If the gas supply line shutoff valve is closed, open it, then repeat the
■If the gas supply line shutoff valve is open, contact a qualified technician.
12