KD- I8 SERIES
INSTALLATION
INSTRUCTIONS
MR. INSTALLER: HAVE YOU CHECKED!
PLACEMENT OF DISHWASHER
0 1. Remove styrofoam packing blocks from top and corrugated motor block packing from rear
of unit after dishwasher is removed from skid.
_
+.
<
4
0 2. Properly
q 4. Installation debris removed .from under dishwasher.
ELECTRICAL CONNECTION
01. Separate 115 volt, 60 hertz, 1 phase branch with a 15 ampere capacity protected by a maximum of 15 ampere fuse size.
0 2. Dishwasher properly grounded.
0 3. All connections in conformance with local electrical code.
PLUMBING -
0 1. Water supply at dishwasher: 20 to 120 P.S.I. pressure, temperature of 140” F. to 160” F. and l/2” O.D. (min.) copper tube.
0 2. Drain lines at least 5/8” O.D. copper tubing or equivalent without drain air gap and with no tight bends (kinks) or other restrictions to prevent complete draining.
03. Drain lines at least g/16” l.D.copper tubing or equivalent with drain air gap and with no tight bends (kinks) or other restrictions to prevent complete draining.
0 4. Compliance with all aspects of local plumbing code.
0 5. Make sure drain hose does not touch any electrical components or terminals.
OPERATIONAL
0 1. All internal packing material and labels and door pads removed.
Place detergent in both compartments of detergent dispenser, close cover(s) and operate dishwasher through complete “Normal Cycle.” Note: KDC has cover over only one of two compartments.
Check: Proper
Detergent
Dishracks, for freedom of movement and adjustment.
THANK YOU MR. INSTALLER:
1.Complete Installation Check List.
2.Leave all literature (Incl. Check List) for customer.
3.Notify dealer that electrical work and plumbing are completed.