BUILT-IN DISHWASHER
KD- I8 SERIES
INSTALLATION
INSTRUCTIONS
MR. INSTALLER: HAVE YOU CHECKED!
PLACEMENT OF DISHWASHER0 1. Remove styrofoam packing blocks from top and corrugated motor block packing from rear
of unit after dishwasher is removed from skid.
_
+.
<
4
0 2. Properly
q 4. Installation debris removed .from under dishwasher.
ELECTRICAL CONNECTION01. Separate 115 volt, 60 hertz, 1 phase branch with a 15 ampere capacity protected by a maximum of 15 ampere fuse size.
0 2. Dishwasher properly grounded.
0 3. All connections in conformance with local electrical code.
PLUMBING -0 1. Water supply at dishwasher: 20 to 120 P.S.I. pressure, temperature of 140” F. to 160” F. and l/2” O.D. (min.) copper tube.
0 2. Drain lines at least 5/8” O.D. copper tubing or equivalent without drain air gap and with no tight bends (kinks) or other restrictions to prevent complete draining.
03. Drain lines at least g/16” l.D.copper tubing or equivalent with drain air gap and with no tight bends (kinks) or other restrictions to prevent complete draining.
0 4. Compliance with all aspects of local plumbing code.
0 5. Make sure drain hose does not touch any electrical components or terminals.
OPERATIONAL0 1. All internal packing material and labels and door pads removed.
Place detergent in both compartments of detergent dispenser, close cover(s) and operate dishwasher through complete “Normal Cycle.” Note: KDC has cover over only one of two compartments.
Check: Proper
Detergent
Dishracks, for freedom of movement and adjustment.
THANK YOU MR. INSTALLER:1.Complete Installation Check List.
2.Leave all literature (Incl. Check List) for customer.
3.Notify dealer that electrical work and plumbing are completed.