30" (76.2 cm) Double Oven Dual Fuel Range

 

30" (76.2 cm) Double Oven Dual Fuel Range

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

KDRS505X

B*

GAS SUPPLY REQUIREMENTS

 

Type of Gas

Natural gas:

This range is design-certified by CSA International for use with

Natural gas or, after proper conversion, for use with LP gas.

This range is factory set for use with Natural gas. See “Gas

 

Conversions” section. The model/serial rating plate located

 

behind the control panel has information on the types of gas

C**

that can be used. If the types of gas listed do not include the

 

type of gas available, check with the local gas supplier.

 

LP gas conversion:

 

Conversion must be done by a qualified service technician.

A

No attempt shall be made to convert the appliance from the gas

 

specified on the model/serial rating plate for use with a different

 

gas without consulting the serving gas supplier. See “Gas

D

Conversions” section.

 

Gas Supply Line

Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in

 

insufficient gas supply. With LP gas, piping or tubing size can

 

 

E***

 

 

 

be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine

 

F

 

 

 

the size and materials used in the system.

 

 

 

 

 

 

 

 

 

 

 

NOTE: Pipe-joint compounds that resist the action of LP gas

 

 

 

 

 

 

must be used. Do not use TEFLON®† tape.

 

 

 

 

 

Flexible metal appliance connector:

A. 35³⁄₄" ± ¹⁄₈" (90.8 ± 0.3 cm)

C. 47¹⁄₈" ± ¹⁄₈" (119.7 ±

0.3 cm)

If local codes permit, a new CSA design-certified, 4 to 5 ft (122

cooktop height (minimum)

overall height (minimum) with

with leveling legs screwed all

leveling legs screwed all the

 

to 152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible

the way in

 

way in**

 

 

 

metal appliance connector may be used for connecting range to

B. Model/serial/rating plates

D. 28¹⁄₂" ± ¹⁄₄" (72.4 ±

0.6 cm)

 

the gas supply line.

(located behind the control

depth with handle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

panel)*

 

E. 26¹⁄₈" ± ¹⁄₈" (66.4 ±

0.3 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F. 29¹⁵⁄₁₆" ± ¹⁄₁₆" (76.0 ±

0.2 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the

*** Model/serial/rating plates may be rotated up from behind the control

 

female pipe threads of the inlet to the appliance pressure

panel for viewing from the front of the range.

 

 

 

regulator.

*** Range can be raised approximately 1" (2.5 cm) by adjusting the leveling

Do not kink or damage the flexible metal tubing when moving

legs.

 

 

 

 

 

the range.

*** Excludes handle. Dimension given is from wall to front of oven door and

Rigid pipe connection:

 

will vary based on electric outlet receptacle installation.

 

 

 

 

 

 

 

The rigid pipe connection requires a combination of pipe fittings

ELECTRICAL REQUIREMENTS

 

 

 

to obtain an in-line connection to the range. The rigid pipe must

 

 

 

 

 

 

 

 

be level with the range connection. All strains must be removed

To properly install your range, you must determine the type of electrical connection

from the supply and fuel lines so range will be level and in line.

you will be using and follow the instructions provided for it here.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range must be connected to the proper electrical voltage and frequency as

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specified on the model/serial number rating plate. The model/serial number rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

plate is located behind the control panel. Refer to the figures in “Product

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions” in the “Location Requirements” section.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This range is manufactured with the neutral terminal connected to the cabinet.

Must include a shutoff valve:

Use a 3-wire, UL listed, 40- or 50-amp power supply cord (pigtail) (see following

 

The supply line must be equipped with a manual shutoff valve.

Range Rating chart). If local codes do not permit ground through the neutral, use

 

a 4-wire power supply cord rated at 250 volts, 40 or 50 amps and investigated for

 

This valve should be located in the same room but external to

 

use with ranges.

 

 

 

 

 

the range opening, such as an adjacent cabinet. It should be in a

 

 

 

 

 

 

 

 

 

 

 

location that allows ease of opening and closing. Do not block

Range Rating*

 

Specified Rating of Power Supply

 

access to shutoff valve. The valve is for turning on or shutting

 

 

 

 

Cord Kit and Circuit Protection

 

off gas to the range.

 

 

 

 

 

 

 

 

 

 

 

 

B

120/240 Volts

120/208 Volts

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8.8 - 16.5 KW

7.8 - 12.5 KW

40 or 50**

 

 

A

 

 

 

 

 

 

A. Gas supply line

16.6 - 22.5 KW

12.6 - 18.5 KW

50

 

 

 

 

 

 

 

 

B. Shutoff valve “open”

** The NEC calculated load is less than the total connected load listed on the

 

 

 

 

 

 

 

 

position

 

 

 

 

 

 

 

C. To range

model/serial rating plate.

 

 

 

 

 

 

 

 

 

 

C

** If connecting to a 50-amp circuit, use a 50-amp rated cord with kit. For 50-amp

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter

connection opening.

 

 

Page 1 of 2

Because Whirlpool Corporation policy includes a continuous commitment to improve

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10345640B

our products, we reserve the right to change materials and specifications without notice.

Instructions packed with product. Specifications subject to change without notice.

1/28/11

Page 1
Image 1
KitchenAid KDRS505X dimensions 30 76.2 cm Double Oven Dual Fuel Range, Type of Gas, Gas Supply Line