| 30" (76.2 cm) Double Oven Dual Fuel Range |
PRODUCT MODEL NUMBERS | PRODUCT DIMENSIONS |
KDRS505X | B* |
GAS SUPPLY REQUIREMENTS |
|
Type of Gas
Natural gas:
This range is
Natural gas or, after proper conversion, for use with LP gas.
● This range is factory set for use with Natural gas. See “Gas |
| |
Conversions” section. The model/serial rating plate located |
| |
behind the control panel has information on the types of gas | C** | |
that can be used. If the types of gas listed do not include the | ||
| ||
type of gas available, check with the local gas supplier. |
| |
LP gas conversion: |
| |
Conversion must be done by a qualified service technician. | A | |
No attempt shall be made to convert the appliance from the gas | ||
| ||
specified on the model/serial rating plate for use with a different |
| |
gas without consulting the serving gas supplier. See “Gas | D | |
Conversions” section. | ||
|
Gas Supply Line
●Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in
| insufficient gas supply. With LP gas, piping or tubing size can |
|
| E*** |
|
| ||||||||||||||
| be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine |
| F |
|
| |||||||||||||||
| the size and materials used in the system. |
|
|
|
| |||||||||||||||
|
|
|
|
|
| |||||||||||||||
| NOTE: |
|
|
|
|
| ||||||||||||||
| must be used. Do not use TEFLON®† tape. |
|
|
|
|
| ||||||||||||||
Flexible metal appliance connector: | A. 35³⁄₄" ± ¹⁄₈" (90.8 ± 0.3 cm) | C. 47¹⁄₈" ± ¹⁄₈" (119.7 ± | 0.3 cm) | |||||||||||||||||
● If local codes permit, a new CSA | cooktop height (minimum) | overall height (minimum) with | ||||||||||||||||||
with leveling legs screwed all | leveling legs screwed all the | |||||||||||||||||||
| to 152.4 cm) long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible | the way in |
| way in** |
|
| ||||||||||||||
| metal appliance connector may be used for connecting range to | B. Model/serial/rating plates | D. 28¹⁄₂" ± ¹⁄₄" (72.4 ± | 0.6 cm) | ||||||||||||||||
| the gas supply line. | (located behind the control | depth with handle |
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| panel)* |
| E. 26¹⁄₈" ± ¹⁄₈" (66.4 ± | 0.3 cm) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| F. 29¹⁵⁄₁₆" ± ¹⁄₁₆" (76.0 ± | 0.2 cm) | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| width |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
● A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the | *** Model/serial/rating plates may be rotated up from behind the control | |||||||||||||||||||
| female pipe threads of the inlet to the appliance pressure | panel for viewing from the front of the range. |
|
| ||||||||||||||||
| regulator. | *** Range can be raised approximately 1" (2.5 cm) by adjusting the leveling | ||||||||||||||||||
● Do not kink or damage the flexible metal tubing when moving | legs. |
|
|
|
| |||||||||||||||
| the range. | *** Excludes handle. Dimension given is from wall to front of oven door and | ||||||||||||||||||
Rigid pipe connection: |
| will vary based on electric outlet receptacle installation. |
|
| ||||||||||||||||
|
|
|
|
| ||||||||||||||||
The rigid pipe connection requires a combination of pipe fittings | ELECTRICAL REQUIREMENTS |
|
|
| ||||||||||||||||
to obtain an |
|
|
| |||||||||||||||||
|
|
|
|
| ||||||||||||||||
be level with the range connection. All strains must be removed | To properly install your range, you must determine the type of electrical connection | |||||||||||||||||||
from the supply and fuel lines so range will be level and in line. | you will be using and follow the instructions provided for it here. |
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ● Range must be connected to the proper electrical voltage and frequency as | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| specified on the model/serial number rating plate. The model/serial number rating | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| plate is located behind the control panel. Refer to the figures in “Product | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dimensions” in the “Location Requirements” section. |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ● This range is manufactured with the neutral terminal connected to the cabinet. | ||||
● Must include a shutoff valve: | Use a | |||||||||||||||||||
| The supply line must be equipped with a manual shutoff valve. | Range Rating chart). If local codes do not permit ground through the neutral, use | ||||||||||||||||||
| a | |||||||||||||||||||
| This valve should be located in the same room but external to | |||||||||||||||||||
| use with ranges. |
|
|
|
| |||||||||||||||
| the range opening, such as an adjacent cabinet. It should be in a |
|
|
|
| |||||||||||||||
|
|
|
|
|
| |||||||||||||||
| location that allows ease of opening and closing. Do not block | Range Rating* |
| Specified Rating of Power Supply | ||||||||||||||||
| access to shutoff valve. The valve is for turning on or shutting |
| ||||||||||||||||||
|
|
| Cord Kit and Circuit Protection | |||||||||||||||||
| off gas to the range. |
|
| |||||||||||||||||
|
|
|
|
|
| |||||||||||||||
|
|
|
| B | 120/240 Volts | 120/208 Volts | Amps |
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 8.8 - 16.5 KW | 7.8 - 12.5 KW | 40 or 50** |
|
|
A |
|
|
|
|
|
| A. Gas supply line | 16.6 - 22.5 KW | 12.6 - 18.5 KW | 50 |
|
| ||||||||
|
|
|
|
|
| B. Shutoff valve “open” | ** The NEC calculated load is less than the total connected load listed on the | |||||||||||||
|
|
|
|
|
|
|
| position | ||||||||||||
|
|
|
|
|
|
| C. To range | model/serial rating plate. |
|
|
| |||||||||
|
|
|
|
|
|
| C | ** If connecting to a | ||||||||||||
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company. | rated cord kits, use kits that specify use with a nominal 1³⁄₈" (34.9 mm) diameter | |||||||||||||||||||
connection opening. |
|
| Page 1 of 2 | |||||||||||||||||
Because Whirlpool Corporation policy includes a continuous commitment to improve | Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10345640B | ||||||||||||||||||
our products, we reserve the right to change materials and specifications without notice. | Instructions packed with product. Specifications subject to change without notice. | 1/28/11 |