Gas and Electric

Gas and Electric

Dimensions

3-prong ground-type outlet should be located on left hand side of cutout 8" (20.3 cm) max. from enclosure sidewall.

Gas supply requirements

Gas supply requirementsWARNING

Explosion Hazard

10" (25.4 cm)

14"

 

(35.6 cm)

Gas supply line should be located in this area on rear or side walls, or the supply line can come up through the floor.

Note: Solid side and bottom of cutout enclosure not shown.

Use a new AGA or CSA approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 14" water column.

Examples of a qualified person include licensed heating

Gas and Electric

Connection Locations

personnel, authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

product rating/serial tag

control support panel

Observe all governing codes and ordinances.

Important: Cooktop must be connected to a regulated gas supply.

regulator (supplied with product) must be

36" (91.4 cm)

Front of Cooktop

A.This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code

installed with arrow up pointing at cooktop bottom

1/2" nipple (not supplied)

AGA or CSA approved flexible stainless steel gas supply line (not supplied)

3-prong ground-type power supply cord

regulated gas

shut off valve supply line (not supplied)

ANSI Z223.1 — latest edition or

CANI — B149.1 or 2*.

B.Input ratings shown on the model/serial rating plate are for elevations up to 2,000 feet (610 m). For elevations above 2,000 feet (610 m), ratings are reduced at a rate of 4% for each 1,000 feet (305 m) above sea level.

Typical Gas and Electric

Connections

Copies of the standards listed may be obtained from:

*CSA International

8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575

C.The cooktop is equipped for use with NATURAL gas. It is design-certified by International Approval Services (I.A.S.) for NATURAL and L.P. gases with appropriate conversion. The model/serial rating plate, located on the underside of the burner box, has information on the type of gas that can be used. If this information does not agree with the type of gas available, check with the local gas supplier.