Microwave Oven Hood Combo Service Manual — LIT 4317216
Original 03/97
Page
PRIMARY, MONITOR, & SECONDARY SWITCH
CHECKOUT PROCEDURE
NOTE: The following chart and strip circuits show the continuity and position of the door switches when the microwave oven door is open and closed.
CONTINUITY TEST CHART
SWITCH | TESTING | DOOR | DOOR |
|
OPEN | CLOSED |
| ||
|
|
| ||
|
|
|
|
|
Primary | Disconnect the | – | + |
|
Interlock | Check from the pink wire (pin 1) to the blue wire (pin 3). |
| ||
|
|
| ||
|
|
|
|
|
Secondary | Disconnect the wires at the Secondary Interlock Switch. |
|
|
|
Check from the common terminal (white wires) to the | – | + |
| |
Interlock |
| |||
|
|
| ||
|
|
|
| |
|
|
|
|
|
| Disconnect the wires from the Monitor Switch. Check |
|
|
|
Monitor | from the common terminal (red/brown wires) to the | + | – |
|
|
|
|
| |
|
|
|
|
|
| Disconnect the wires from the Oven Lamp Switch. |
|
|
|
| Check from the common terminal (blue wire) to the | + | _ |
|
Oven |
|
|
| |
|
|
|
| |
Lamp | Disconnect the wires from the Oven Lamp Switch. |
|
|
|
|
|
|
| |
| Check from the common terminal (blue wire) to the | – | + |
|
|
|
|
| |
|
|
|
|
|
|
| (+) = CONTINUITY | ||
|
|
DOOR OPEN
L1 |
|
|
| N |
|
| N.C. |
|
|
| C | N.O. |
|
|
SECONDARY | OVEN LIGHTS | MONITOR | RELAY | |
INTERLOCK |
| SWITCH | SWITCH | #2 |
SWITCH |
|
|
|
|
DOOR CLOSED |
|
|
|
|
L1 |
|
|
| N |
|
| N.C. |
|
|
| C | N.O. |
|
|
SECONDARY | OVEN LIGHTS | MONITOR | RELAY | |
INTERLOCK |
| SWITCH | SWITCH | #2 |
SWITCH |
|
|
|
|