The gas mains system must comply with local regulations.
The paragraph on “national legislation reference” shows the
local legislation specific to the country of destination.
Should there be no information regarding your country of
interest, ask for further details from the installer.
The connection of the hob to the gas mains network or gas
cylinder must be done using a rigid copper or steel pipe with
parts that comply with local standards, or using a flexible
stainless steel pipe with continuous surfaces that comply with
local standards. The flexible metallic pipe should be no longer
than 2 linear metres.
Before connecting the pipe with the rubber part (A), insert
the seal (B) provided, that complies with EN 549.
Warning:if you use a stainless steel flexible pipe, it must be
installed in such a way that it does not come into contact with
moving cabinetry like drawers or kitchen cupboards and passes at
a point free of obstacles where it can be examined in its entirety.
After connecting to the gas mains, use soap and water to
check there are no leaks.
Gas connection
The electrical connections must comply with local
standards.
Information on the voltage and power absorbed are shown on
the serial no. plaque.
The appliance must be earthed by law.
When installing the appliance you must make sure there is a
multipolar switch with contact opening equal or greater than
3mm.
If necessary, the power cable must be replaced exclusively
with a cable that is identical to the original one provided
(H05V2V2-F T90°C or H05RR-F type). Please contact the
Customer Care Centre.
Do not use extension cables.
The manufacturer declines all responsibility for damage
to persons, pets or goods as a result of failure to comply
with the regulations above.
Electrical connection
L
Earth
(yellow/green)
N
12