KitchenAid KIRD801V, KIRD862V, KIRD861V Maximum Length of Vent System, Vent Piece, 6 15.2 cm Round

Models: KIRD862V KIRD861V KIRD801V

1 3
Download 3 pages 63.72 Kb
Page 3
Image 3
Maximum Length of Vent System

VentLengthVent Piece6" (15.2 cm) RoundExample Vent SystemRecommended vent system length:Manual backgroundManual backgroundManual backgroundManual background ® 30" (76.2 CM) and 36" (91.4 CM) Retractable Downdraft Vent System

VENTING REQUIREMENTS

It is recommended that you use round vent instead of rectangular vent, especially if elbows are required. If rectangular vent is required, it should be transitioned to 6" (15.2 cm) round vent as soon as possible.

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Maximum Length of Vent System

Vent

Length

 

 

6" (15.2 cm) round

35 ft (8.9 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

35 ft (8.9 m)

 

 

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

 

 

90° elbow

5.0 ft

 

(1.5 m)

 

 

6" (15.2 cm)

0.0 ft

wall cap

(0.0 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

 

 

6" (15.2 cm) to 3¹⁄₄" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

 

 

3¹⁄₄" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

transition

 

Example Vent System

C

6 ft

Manual background (1.8 m) Manual background

A B

Manual background 2 ft (0.6 m)

D

A. Blower motor

B.Transition

C.90° elbows

D.6" backdraft damper (supplied)

IMPORTANT: Make sure there is proper clearance within the wall or floor before making exhaust vent cutouts.

Use heavy (rigid) metal vent.

Venting system must terminate to the outside.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-type wall caps.

Do not install 2 elbows together.

Do not use plastic or metal foil vent.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

Use no more than three 90° elbows

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than one elbow is used.

Use clamps to seal all joints in the vent system.

Use caulking tape to seal the exterior wall or floor opening around cap.

Do not cut joist or stud. If vent cutout falls over a joist or stud, a supporting frame must be constructed.

Flexible metal vent is not recommended. If it is used, calculate each foot of flexible vent as 2 ft (0.6 m) of rigid metal vent. Flexible elbows count twice as much as standard elbows.

Recommended vent system length:

For either interior-mounted or exterior-mounted blower installations, the vent system length should not exceed the maximum lengths listed in the Maximum Length of Vent System chart.

6" (15.2 cm) to 3¹⁄₄" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

 

 

 

 

Page 3 of 3

Because Whirlpool Corporation policy includes a continuous commitment to improve

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10187117

our products, we reserve the right to change materials and specifications without notice.

Instructions packed with product. Specifications subject to change without notice.

11-06-08

Page 3
Image 3