Image 5

Door Hinge Holes

The views of the top and bottom hinge pin hole show a right- hand hinge. Mirror the image for a left-hand hinge.

We recommend using a C-clamp and two pieces of scrap wood (front and back) to help reinforce the overlay frame when drilling the hinge pin holes.

1.Using a ³⁄₈" Brad point doweling drill bit, drill a hole, ⁹⁄₃₂"

(7.1 mm) deep, into the top of the overlay panel for the top hinge pin. Remove the excess wood, surrounding the hole, by using the rotary tool to complete the hinge depression as shown.

Top View

NOTE: It is recommended that you do not install the wine cellar near an oven, radiator, or other heat source. Do not install in a location where the temperature will fall below 55°F (13°C). For best performance, do not install the wine cellar behind a cabinet door or block the base grille.

¹⁄₄" (6.35 mm)

A

⁷⁄₃₂"

(5.5 mm)

¹⁵⁄₃₂"

(12 mm)

Front Surface

Back Surface

³⁄₈"

(9.5 mm)

2¹⁄₂" (6.35 cm)

Electrical Requirements

A. Diameter ³⁄₈" (9.53 mm)

2.Using a ³⁄₈" Brad point doweling drill bit, drill a hole, ⁹⁄₃₂"

(7.1 mm) deep, in the bottom of the overlay frame for the bottom hinge pin. Remove the excess wood, surrounding the hole, by using the rotary tool to complete the hinge depression as shown.

Bottom View

WARNING

⁷⁄₃₂"

(5.5 mm)

A

³⁄₈"

(9.5 mm)

Back Surface

Front Surface

¹⁵⁄₃₂"

(12 mm)

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

A. Diameter ³⁄₈" (9.53 mm)

Location Requirements

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from wine cellar.

Failure to do so can result in death, explosion, or fire.

To ensure proper ventilation for your wine cellar, allow for a ¹/" (6.35 mm) space on each side and at the top. When installing your wine cellar next to a fixed wall, leave 2¹⁄₂" (6.35 cm) minimum clearance on the hinge side to allow for the door to swing open.

Before you move your wine cellar into its final location, it is important to make sure you have the proper electrical connection.

Recommended grounding method

A 115 Volt, 60 Hz., AC only, 15– or 20–amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your wine cellar be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord.

NOTE: Before performing any type of installation, cleaning, or removing a light bulb, unplug wine cellar or disconnect power.