Rear Mounting - Blower Motor
NOTE: Optional blower motor mounting position (opposite side). The blower motor box assembly can also be moved to the opposite side (rear) of the vent box.
3.Disconnect the wire connector from the blower motor.
B
A
A.Panel
B.Blower motor - rear mounting
1.Loosen the 2 hex/slotted head screws that attach the top bracket that secures the motor to the vent box enough to slide the bracket into the “Z” slots. This will move the bracket away from the top mounting lip of the blower box and allow it to tilt away from the vent box panel.
A
B
A B
A. Blower motor
B. Wire connector
4.Remove panel from the opposite side of blower motor. Loosen the 2 hex/slotted head screws that attach the top bracket that secures the panel to the vent box enough to slide the bracket into the “Z” slots. This will move the bracket away from the top mounting lip of the panel and allow it to tilt away from the vent box panel.
A
B
B
A. Bracket with “Z” slots
B. Hex/slotted head screws (2)
B | 5. Lift up the panel from the bottom mounting channel. |
|
A. Bracket with “Z” slots
B. Hex/slotted head screws (2)
2.Lift up the blower box from the bottom mounting channel.
B
A
A. Blower mounting channel
B. Panel
B
A
A. Blower box
B. Bottom mounting channel