KitchenAid W10268948C VentingRequirements, Vented Models Only, Installation Dimensions

Models: W10268948C

1 32
Download 32 pages 31.94 Kb
Page 6
Image 6
Non-vented (recirculating) Installations

Non-vented (recirculating) Installations

For non-vented (recirculating) installations, optional Recirculation Kit Part Number W10271501, must be used. This kit includes a new lower chimney cover that replaces the lower chimney cover shipped with the range hood, a diverter with extensions, 2 grids for inserting into the lower chimney, and a charcoal filter.

Installation Dimensions 11¹³⁄₁₆"

(30.0 cm)

10¼" (26. 0 cm)

Upper VentingRequirements

chimney

 

 

 

25⁵⁄₈"(65.1 cm)

 

3⁹⁄₁₆"

 

 

 

min.

 

 

 

 

37¼" (94.6 cm)

 

(9.1 cm)

 

 

 

 

Vent

 

 

max.

 

 

 

 

 

 

 

 

 

 

21¼"

overall chimney

 

 

 

 

opening

 

 

 

 

on each

(54.0 cm)

height

 

 

 

 

side

lower

 

 

 

 

 

 

 

 

12⁵⁄₈"

 

 

 

chimney

 

 

 

 

 

height

 

 

(32.0 cm)

 

 

 

 

 

 

 

5⁵⁄₁₆"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2⁷⁄₁₆"

(13.5 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(6.2 cm)

 

 

 

 

 

Installation Dimensions

30" (76.2 cm) or 36" (91.4 cm) cabinet opening width

(if installed between cabinets)

See Note*

X*

18" (45.7 cm) min. clearance upper cabinet to countertop

36" (91.4 cm) countertop height

*NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10271503 is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.

IMPORTANT:

Minimum distance “X”: 30" (76.2 cm)

Suggested maximum distance “X”: 36" (91.4 cm)

Chimneys can be adjusted for ceilings between 8' ³⁄₈" (2.55 m) and 9' 6" (2.90 m) in both vented and non-vented (recirculating) applications.

If you have shorter ceilings, the upper chimney can be shortened by removing up to 5¼" (13.3 cm) off the bottom for vented applications and 11¼" (28.6 cm) for non-vented (recirculating) applications. This will give you a minimum ceiling height of

7' 8" (2.34 m).

NOTE: If the upper chimney is cut for your application, the lower chimney bracket will not be used.

VentingRequirements

(Vented Models Only)

Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-type wall caps.

Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61.0 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

The size of the vent should be uniform.

Cold weather installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup air

Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale.

Consult your HVAC professional for specific requirements in your area.

Venting Methods

This canopy range hood is factory set for venting through the roof or through the wall.

A 6" (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6" (15.2 cm) round.

6

Page 6
Image 6
KitchenAid W10268948C VentingRequirements, Vented Models Only, Installation Dimensions, Cold weather installations