Complete Preparation

3.Drill ³⁄₃₂" (2.4 mm) pilot holes for installation into wood. The screws provided are for mounting the range hood into wood.

Mounting into drywall or plaster is not recommended.

4.Attach each bracket to the wall with 2 - #10 Phillips head mounting screws. Tighten screws securely.

Complete Preparation

1.Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the range hood. See the “Venting Requirements” section.

2.Determine the location where the power supply cable will be run through the wall.

NOTE: For wiring flexibility, the terminal box is external to the range hood motor. About 24" (61.0 cm) of wire connects the terminal box to the range hood motor.

Check that the lower chimney cover will hide the selected location.

3.Drill a 1¹⁄₄" (3.2 cm) hole at this location.

4.Pull enough power supply cable through the wall to allow for easy connection to the terminal box.

4.Install the 2 vent extension pieces onto the diverter pushing them until they stop.

B

A

A.Diverter

B.Exhaust extension

5.Using 2 or more people, lift the range hood and place the mounting hood brackets over the mounting screws. Securely tighten the screws.

InstallRange Hood

1.Use a flat-blade screwdriver and tighten the 2 leveling screws located close to the range hood mounting brackets.

AInstallRange Hood

A. Leveling screw

Vented Installations

Go to Step 5.

Non-vented (recirculating) Installations

NOTE: Non-vented (recirculating) installation is not allowed over cooktops with BTU ratings of 60,000 or higher.

2.Install the non-vented (recirculating) conversion kit ordered for your range hood.

3.Fit the diverter over the vent motor exhaust and push down to seat. Check that the diverter exhaust outlets are parallel with the vent motor sides so that they align with the vent cover openings in the lower chimney.

A

B

C

A.Diverter

B.Vent motor exhaust

C.Vent motor

6.Level the range hood. Adjust the 2 leveling screws (see Step 1) as needed.

Make Electrical Connection

Vented InstallationsWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Remove terminal box cover.

3.Remove the knockout in the terminal box and install a UL listed or CSA approved ¹⁄₂" strain relief.

4.Center the wiring hole in the terminal box over the 1¼" (3.2 cm) diameter wiring hole in the wall. Mark the

2 terminal box mounting holes. Drill ¹⁄₈" (3.0 mm) diameter holes as needed for your installation.

5.Run 3 wires, black, white and green (or bare), from home power supply through strain relief into terminal box.