KitchenAid W10331007B MakeElectrical Connectionsfor In-Line BlowerMotor System, C D E F G H I

Models: W10331007B

1 36
Download 36 pages 1.97 Kb
Page 12
Image 12
MakeElectrical Connectionsfor In-Line BlowerMotor System

MakeElectrical Connectionsfor In-Line BlowerMotor System

Electrical Shock HazardWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Electrical Connection Inside In-line Blower System

1.Disconnect power.

2.Connect the wires from the wiring conduit to the wires from the motor electrical plug cable inside the in-line blower housing terminal box.

Replace all parts and panels before operating.WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire in terminal box.

Failure to do so can result in death or electrical shock.

8.

Connect the green (or yellow/green) ground wire to the

 

green/yellow ground wire (H) in the terminal box using UL

 

listed wire connectors.

9.

Reinstall the in-line blower terminal box cover and screw.

10.

Reinstall the front cover of the in-line blower housing and

 

secure it with 10 mounting screws.

B

A

C

D

Failure to do so can result in death or electrical shock.Electrical Connection Inside In-line Blower System E

F

G

H

I

Electrical Connection Inside Range Hood Between In-line Blower System and Range Hood

1.

With the range hood mounted (see the “Install Range Hood”

 

section), locate the wiring cable connector inside the range

 

hood.

2.

Connect the 6-wire connector assembly supplied with the

 

in-line blower motor system to the mating cable connector

 

from the range hood.

3.

Locate the terminal box inside the range hood and install a

A. UL listed or CSA approved

F. Blue wires

¹⁄₂" (1.3 cm) wiring conduit

G. Gray wires

B. UL listed wire connectors

H. Green (or yellow/green)

C. Black wires

and green/yellow wires

D. White wires

I. Motor electrical plug cable

E. Red wires

 

3.Use UL listed wire connectors and connect the black wires

(C)together.

4.Use UL listed wire connectors and connect the white wires

(D)together.

5.Use UL listed wire connectors and connect the red wires (E) together.

6.Use UL listed wire connectors and connect the blue wires (F) together.

7.Use UL listed wire connectors and connect the gray wires (G) together.

 

¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see

 

“Complete Preparation” in the “Prepare Location” section).

4.

Run the wire ends from the 6-wire connector assembly

 

through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire

 

length to make the wiring connections. Tighten the strain

 

relief screws.

5.

Connect the wires from the 6-wire connector assembly to the

 

wires from the wiring conduit inside the range hood terminal

 

box.

12

Page 12
Image 12
KitchenAid W10331007B installation instructions MakeElectrical Connectionsfor In-Line BlowerMotor System, C D E F G H I