MakeElectrical Connectionsfor In-Line BlowerMotor System
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Electrical Connection Inside In-line Blower System
1.Disconnect power.
2.Connect the wires from the wiring conduit to the wires from the motor electrical plug cable inside the
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
8. | Connect the green (or yellow/green) ground wire to the |
| green/yellow ground wire (H) in the terminal box using UL |
| listed wire connectors. |
9. | Reinstall the |
10. | Reinstall the front cover of the |
| secure it with 10 mounting screws. |
B
A
C
D
E
F
G
H
I
Electrical Connection Inside Range Hood Between
1. | With the range hood mounted (see the “Install Range Hood” |
| section), locate the wiring cable connector inside the range |
| hood. |
2. | Connect the |
| |
| from the range hood. |
3. | Locate the terminal box inside the range hood and install a |
A. UL listed or CSA approved | F. Blue wires |
¹⁄₂" (1.3 cm) wiring conduit | G. Gray wires |
B. UL listed wire connectors | H. Green (or yellow/green) |
C. Black wires | and green/yellow wires |
D. White wires | I. Motor electrical plug cable |
E. Red wires |
|
3.Use UL listed wire connectors and connect the black wires
(C)together.
4.Use UL listed wire connectors and connect the white wires
(D)together.
5.Use UL listed wire connectors and connect the red wires (E) together.
6.Use UL listed wire connectors and connect the blue wires (F) together.
7.Use UL listed wire connectors and connect the gray wires (G) together.
| ¹⁄₂" (1.3 cm) UL listed or CSA approved strain relief (see |
| “Complete Preparation” in the “Prepare Location” section). |
4. | Run the wire ends from the |
| through the ¹⁄₂" (1.3 cm) strain relief, leaving enough wire |
| length to make the wiring connections. Tighten the strain |
| relief screws. |
5. | Connect the wires from the |
| wires from the wiring conduit inside the range hood terminal |
| box. |
12