6.Connect the same color wires to each other (black to black, white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from the wiring conduit to the green (or bare) ground wire from the home power supply using UL listed wire connectors (see the “Make Electrical Power Supply Connections to Range Hood” section).
E
A
B
B
A
C
D
E
F
G
H
I
C
D F
A. White wires B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires E. Home power supply
F. UL listed or CSA approved ¹⁄₂" (1.3 cm) strain relief
3. | Use UL listed wire connectors and connect black wires (B) |
| together. |
4. | Use UL listed wire connectors and connect white wires (A) |
A. UL listed or CSA approved | E. Red wires |
¹⁄₂" (1.3 cm) wiring conduit | F. Blue wires |
B. UL listed wire connectors | G. Gray wires |
C. Black wires | H. Green (or green/yellow) wire |
D. White wires | I. |
7.Go to “Make Electrical Power Supply Connection to Range Hood” section.
MakeElectricalPower Supply Connection to
Range Hood
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Disconnect power.
2.Locate terminal box inside of the range hood.
A
B
A. Terminal box cover
B. Knockout in canopy back into terminal box
together. |
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
NOTE: When using an
5.Connect green (or bare) ground wire from home power supply to the green/yellow ground wire (D) in terminal box using UL listed wire connectors.
6.Install terminal box cover.
7.Check that all light bulbs are secure in their sockets.
8.Reconnect power.