UNDER THE CABINET INSTALLATION – REAR VENT

Preparation before installation

NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING.

-Decide the location of the venting pipe from the hood to the outside. Refer to Figure 6.

-A straight, short venting run will allow the hood to perform more efficiently.

-Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.

-Temporarily wire the hood to test for proper operation before installing.

-Peel protective film off the hood (if any).

-For installing under the cabinet with recessed bottom, attach 4-inch wide wood filler strips (not included) on each side. Refer to Figure 7.

-Measure and create access opening for electrical wires under the cabinet or access opening for the electrical wires at the rear of the hood.

-Remove the screws on the vent cover (rear) and cut along the line of the inner vent cover (rear) opening. Refer to Figure 8.

-Cut the vent cover (rear) opening and reverse to the other side. Refer to Figure 9. Reattach the vent cover (rear).

Figure 6

Inner Vent

Cover (Rear)

Figure 7

Reversed

Vent Cover

(Rear)

Figure 8

Figure 9

8