mounting screws (not provided) on theFigure 12 wall, leaving 1/8 away from the wall.
2.Align
3.For safety purposes, extra knockout holes on the back of the hood are provided. Knockout the holes. Remove the baffle filters and attach screws to the wall by accessing underneath the hood.
CAUTION: MAKE SURE HOOD IS SUCURE BEFORE RELEASING
Wiring to Power Supply
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS
RANGE HOOD MUST BE PROPERLY
GROUNDED. MAKE SURE THIS IS DONE
BY SPECIALIZED ELECTRICIAN IN
ACCORDANCE WITH ALL APPLICABLE
NATIONAL AND LOCAL ELECTRICAL
CODES. BEFORE CONNECTING WIRES,
SWITCH POWER OFF AT SERVICE PANEL
AND LOCK SERVICE PANEL TO PREVENT
POWER FROM BEING SWITCHED ON
ACCIDENTALLY.
4.Connect the electrical wires.
-Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown on Figure 12.
-If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. Make sure wires
do not slip between motor or any moving parts to prevent any damage.
Duct Cover Installation
Figure 15
5.Mark the position of the duct cover- mounting bracket. Use referenceEfrom Table 2 and measurements on page 14- 15. Attach and secure duct cover- mounting bracket with two screws (not provided). Refer to Figure 13. NOTE: Inner duct cover will cover the duct cover- mounting bracket.
6.Use aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to make
9