Kobe Range Hoods CH9148SQB Duct Cover Installation, Safety Warning, Wiring to Power Supply

Models: CH-191 CH9130SQB CH9142SQB CH9148SQB CH9136SQB

1 27
Download 27 pages 5.94 Kb
Page 11
Image 11
Duct Cover Installation
Figure 13
Figure 14

mounting screws (not provided) on theFigure 12 wall, leaving 1/8￿ away from the wall.

2.Align hood-mounting bracket to the screws on the wall and hook hood into place as shown in Figure 11. Tighten screws to secure hood to the wall.

3.For safety purposes, extra knockout holes on the back of the hood are provided. Knockout the holes. Remove the baffle filters and attach screws to the wall by accessing underneath the hood.

CAUTION: MAKE SURE HOOD IS SUCURE BEFORE RELEASING

Wiring to Power Supply

Manual backgroundSAFETY WARNING

RISK OF ELECTRICAL SHOCK. THIS

RANGE HOOD MUST BE PROPERLY

GROUNDED. MAKE SURE THIS IS DONE

BY SPECIALIZED ELECTRICIAN IN

ACCORDANCE WITH ALL APPLICABLE

NATIONAL AND LOCAL ELECTRICAL

CODES. BEFORE CONNECTING WIRES,

SWITCH POWER OFF AT SERVICE PANEL

AND LOCK SERVICE PANEL TO PREVENT

POWER FROM BEING SWITCHED ON

ACCIDENTALLY.

4.Connect the electrical wires.

-Connect three wires (black, white and green) to house wires and cap with wire connectors. Connect according to color: black to black, white to white, and green to green as shown on Figure 12.

-If necessary to hide the electrical wire connections, push wires back into the wiring box. Access the wire connections underneath the hood. Make sure wires

do not slip between motor or any moving parts to prevent any damage.

Duct Cover Installation

Figure 15

5.Mark the position of the duct cover- mounting bracket. Use referenceEfrom Table 2 and measurements on page 14- 15. Attach and secure duct cover- mounting bracket with two screws (not provided). Refer to Figure 13. NOTE: Inner duct cover will cover the duct cover- mounting bracket.

6.Use aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to make

9

Page 11
Image 11
Kobe Range Hoods CH9148SQB, CH9136SQB, CH9142SQB, CH9130SQB Duct Cover Installation, Safety Warning, Wiring to Power Supply