KOBE Brand Range Hood
Model No. IS2036GS IS2042GS IS-20 SERIES “ISLAND GLASS CANOPY”
READ AND SAVE THESE INSTRUCTIONS
CONTENTS
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING
INJURY, OBSERVE THE FOLLOWING
IMPORTANT SAFETY INSTRUCTIONS
WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL
What to Do In The Event Of a Range Top Grease Fire
Box 2 of
COMPONENTS OF PACKAGE Must keep all material for returns or refunds
Box 1 of
Box 3 of
C = Preferred Height of Counter Top to Hood Bottom Recommended 30 to
SAFETY WARNING
INSTALLATION
Important Peel protective film off the hood and duct covers, if any
Preparation before Installation
Advance Planning
SAFETY WARNING
Wiring to Power Supply
Ductwork Installation
Duct Cover Installation
Final Assembly
OPERATION INSTRUCTIONS
USE PAPER TOWEL ON STAINLESS STEEL
MAINTENANCE
CAUTION NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. DO NOT
SAFETY WARNING
To Replace Halogen Light Bulbs
CAUTION HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL
With Glass and Duct Cover W x D x H OPTIONAL ACCESSORIES
SPECIFICATIONS
HALOGEN LIGHTS HOOD DIMENSION W x D x H HOOD DIMENSION
WEIGHT lbs SPEED Air Capacity cfm Sone dB
MEASUREMENTS & DIAGRAMS
All measurements are in millimeter
IS2042GS
PARTS LIST
MODEL NO. IS2036GS
Box 1 of
MODEL NO. IS2036GS IS2042GS RECIRCULATING KIT Item No. RD-0020
Sold Separately
CIRCUIT DIAGRAM
MODEL NO. IS2036GS IS2042GS
Solution
Trouble Shooting
Issue
Possible Cause
2. PLEASE INSPECT CONTENTS OF PACKAGES CAREFULLY UPON RECEIVING
DISCLAIMER
DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR WARRANTY
CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS
TWO-YEAR WARRANTY SERVICE PERIOD
WARRANTY
WARRANTY CERTIFICATE
CONDITIONS
CONSEQUENTIAL DAMAGE
SERVICE
Email customer.service@KOBERangeHoods.com
IMPLIED WARRANTIES/STATE LAW
RECORD THE FOLLOWING INFORMATION FOR YOUR RECORD
PRODUCT REGISTRATION
Register Your Product
KOBE Range Hoods 10505 Valley Blvd Suite # El Monte, CA 91731 USA
VER.080115
Page
Modèles No. IS2036GS IS2042GS SÉRIES IS-20 «ISLAND GLASS CANOPY»
INSTRUCTIONS D’INSTALLATION ET MANUEL D’OPÉRATION
Hotte de cuisine de marque KOBE
LIRE ATTENTIVEMENT TOUTE LES INSTRUCTIONS AVANT DE DÉBUTER
LIRE ET CONSERVER CES INSTRUCTIONS
CONTENU
DIRECTIVES DE SÉCURITÉ IMPORTANTES
VEUILLEZ LIRE ATTENTIVEMENT CETTE SECTION AVANT L’INSTALLATION
AVERTISSEMENT
MISE EN GARDE
Boîte 1 de
COMPOSANTS DE L’EMBALLAGE
Garder tous les matériaux pour retours ou remboursements
Boîte 2 de
TABLEAU
INSTALLATION
AVERTISSEMENT DE SÉCURITÉ
Canalisation ronde 6”
Préparation avant l’installation
Planification préliminaire
Solives de plafond
AVERTISSEMENT DE SÉCURITÉ
Installation du système de conduits
Câblage jusqu’à l’alimentation en électricité
Installation de l’enveloppe de conduit
Assemblage final
Halogen light control = Commande de lampe halogène
MODE D’EMPLOI
Speed control = Commande de vitesse
Power control = Commande d’alimentation
AVERTISSEMENT DE SÉCURITÉ
ENTRETIEN
Nettoyage de la surface de la hotte
Pour remplacer les ampoules de lampe halogène
DIMENSION DE LA HOTTE Incluant le verre et l’enveloppe de conduit
SPÉCIFICATIONS
ÉVACUATION COMMANDES LAMPES HALOGÈNES DIMENSION DE LA HOTTE L x P x H
L x P x H ACCESSOIRES EN OPTION
Front of hood = Avant de la hotte
DIMENSIONS ET SCHÉMAS
Toutes les dimensions sont en millimètres
ARTICLE NO. IS20S Unité de ventilation
LISTE DE PIÈCES
MODÈLES IS2036GS NO. IS2042GS
Boîte 2 de
Article No. RD-0020
MODÈLES IS2036GS NO. IS2042GS
Trousse de recirculation
Vendus séparémen
MODÈLES IS2036GS NO. IS2042GS
SCHÉMA DE CIRCUITS
Transformer = Transformateur
Cause probable
Trouble Shooting
Problème
Vérifiez l’installation du clapet
Vérifiez l’installation du conduit
Le clapet n’est pas bien installé ou
manque à l’installation
AVIS DE NON-RESPONSABILITÉ
CERTIFICAT DE GARANTIE
GARANTIE
PÉRIODE DE SERVICE GARANTIE DEUX ANS
CONDITIONS
Courriel customer.service@koberangehoods.com
SERVICE
Pour le service, veuillez communiquer avec KOBE Range Hoods, Inc
DOMMAGE INDIRECT
GARDEZ L’INFORMATION SUIVANTE POUR VOS DOSSIERS
ENREGISTREMENT DU PRODUIT
Enregistrez votre produit
KOBE Range Hoods 10505 Valley Blvd Suite # El Monte, CA 91731 USA
Page
INSTRUCCIONES DE INSTALACIÓN Y MANUAL DE OPERACIÓN
Campana de Extracción KOBE
Modelo No. IS2036GS IS2042GS SERIE IS-20 “CAMPANA DE VIDRIO DE ISLA”
LEA Y CONSERVE ESTAS INSTRUCCIONES
LEA CUIDADOSAMENTE TODAS LAS INSTRUCCIONES ANTES DE COMENZAR
CONTENIDO
LESIÓN PERSONAL, TOME EN CUENTA LO SIGUIENTE
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIO, ELECTROCUCIÓN O
PRECAUCIÓN
Caja 2 de
COMPONENTES DEL PAQUETE
Caja 1 de
Caja 3 de
TABLA
ADVERTENCIA DE SEGURIDAD
INSTALACIÓN
Preparación antes de la Instalación
Planificación Anticipada
ADVERTENCIA DE SEGURIDAD
Cableado Hacia la Fuente de Alimentación
Instalación de la Red de Conductos
Figura
Instalación de la Cubierta de Conductos
Ensamblaje Final
INSTRUCCIONES DE OPERACIÓN
Control Encendido/Apagado
ABRASIVOS. NO UTILICE TOALLAS DE PAPEL SOBRE EL ACERO INOXIDABLE
MANTENIMIENTO
PRECAUCIÓN NUNCA UTILICE LIMPIADORES, ALMOHADILLAS O PAÑOS
ADVERTENCIA DE SEGURIDAD
Para Reemplazar los Focos de la Lámpara de Halógeno
DIMENSIONES DE LA
ESPECIFICACIONES
DIMENSIONES DE LA
CAJA 1 DE
Parte Frontal de la Campana
MEDIDAS Y DIAGRAMAS
Todas las medidas están en milímetros
ARTICULO NO. IS20S Unidad de Ventilador
LISTADO DE PIEZAS
MODELO IS2036GS NO.IS2042GS
Caja 2 de MODELO NO. IS2036GS / IS2042GS Vidrio
Artículo No. RD-0020
MODELO IS2036GS NO.IS2042GS
KIT DE RECIRCULACIÓN
Vendidos por Separado
Brown = Café
DIAGRAMA DE CIRCUITO
Blue = Azul
Red = Rojo
Posible Causa
Guía para la Solución de Problemas
Problema
Solución
CLÁUSULA DE EXENCIÓN
PERIODO DE SERVICIO DE LA GARANTÍA DE DOS AÑOS
GARANTÍA
CERTIFICADO DE GARANTÍA
CONDICIONES
GARANTÍAS IMPLÍCITAS/LEY ESTATAL
customer.service@KOBERangeHoods.com
DAÑOS EMERGENTES
SERVICIO
ESCRIBA LA SIGUIENTE INFORMACIÓN PARA SUS ARCHIVOS
REGISTRO DEL PRODUCTO
¡Registre su Producto
KOBE Range Hoods 10505 Valley Blvd Suite # El Monte, CA 91731 USA