Fuse Replacement

1.Move the POWER SWITCH to the “OFF” position.

2.Disconnect the power cord and wait until the unit is completely cool.

3.Locate the fuse (see diagram). Use a screwdriver to remove the fuse cover, then remove the used fuse.

4.Install a new fuse with the correct rating. Replace the fuse cover.

Lamps

Fuse Rating

EYB, EHJ, EVD

250Volt

125Volt

For 36V400w

T3.15A

T10A

 

 

 

For 24V250w

T3.15A

T6.3A

 

 

 

For 82V360w

 

T6.3A

 

 

 

Lens and Glass Cleaning and Maintenance

Lens and Glass Cleaning and Maintenance

1.Clean the PROJECTION MIRROR, PROJECTION LENS, Fresnel lens (inside), and STAGE GLASS with a clean, lint-free cloth.

Note:

Fresnel lens is on inside of TOP COVER. Turn clips to remove. When replac- ing, make sure the “UP” label faces the STAGE GLASS side.

10KODAK EKTALITE E30/E31 OVERHEAD PROJECTORS