Kodak III manual Maintenance, Lamp Tips

Models: III

1 38
Download 38 pages 46.12 Kb
Page 25
Image 25

Maintenance

To ensure a long life and trouble-free operation for your projector:

Allow the air to flow freely around the projector.

Do not recirculate warm air.

Keep the projector dust free.

If your projector is chilled, bring it to room temperature before operating.

Projection Lamps Quartz-halogen 82 V projection lamps

Included: EXR, 300 W (35-hour lamp life at full lamp/medium-brightness)

Sampling of other lamps:

EXY (200 hours/less brightness)

EXW (15 hours/maximum brightness)

FHS (70 hours/medium brightness)

Use combinations of lamp brightness, plus half- and full-lamp settings to approximate image brightness in multi-projector presentations.

Desired

EKTAGRPAHIC III

Brightness

Projector Lamp

Maximum

EXW

High

EXR

Medium

FHS

Low

EXY

Lamp Tips

Projector operation on line voltages above 125 volts greatly

 

reduces the lamp life.

 

Unplug the projector before changing the lamp.

 

Allow for unrestricted flow of air to the exhaust vent to prolong

 

lamp life.

 

Gently wipe off any fingerprints with a soft cloth moistened with

 

rubbing alcohol.

 

KODAK EKTAGRAPHIC III Slide Projector

21

 

 

 

Page 25
Image 25
Kodak III manual Maintenance, Lamp Tips