![Finish the Installation](/images/new-backgrounds/41428/414289x1.webp)
Finish the Installation
1.With the ribs of the sprayhead facing up, attach the sprayhead to the waterway.
2.Using a 3/16” hexagonal key, secure the sprayhead to the waterway with the 2 securing screws (supplied). Do not overtighten.
3.Check the sprayhead for upward and downward movement and that it sits squarely within the housing.
4.Place the nozzle membrane over the sprayhead
Note! For optimum performance make sure that the membrane is applied evenly.
5.Tilt the sprayhead downward so that the ribs on top of the sprayhead are exposed.
6.Insert the grooves of the sprayface over the ribs of the sprayhead.
7.Press the sprayface down to cover the sprayhead, as illustrated.
8.Tilt the sprayhead upwards to expose the setscrew holes on the bottom of the sprayhead.
Important! The setscrews must be flush with the edge of the sprayface frame. If the setscrews protrude outside of the sprayface frame product damage will occur.
9.Using a 7/64” hexagonal key, turn the setscrews
Waterway
Sprayhead
Hex Screws
Ribs
Groove
Nozzle
Membrane
Attach the Sprayhead
Ribs
Finished Wall
Sprayface
Setscrews
Attach the Sprayface
5 |