Troubleshooting (cont.)

Symptoms

Probable Causes

Recommended Action

3. Pump operates but

A.

Neckjet line is blocked.

A.

Disconnect neckjet hoses and

neckjets do not turn on.

 

 

 

remove blockage.

Indicator bar on user

B.

Wiring harness from neckjet to

B.

Check wiring for proper

keypad is NOT flashing.

 

control is loose, disconnected or

 

connections. Replace wiring

 

 

damaged.

 

harness if necessary.

 

C.

Butterfly valve does not work.

C.

Replace butterfly valve.

 

D.

Control does not work.

D.

Replace control.

4. Water flows from neckjets,

A.

Wiring harness from neckjet

A.

Check wiring for proper

but neckjets do not pulse.

 

pulse canister to control is loose,

 

connections. Replace wiring

 

 

disconnected or damaged.

 

harness if necessary.

 

B.

Pulse canister does not work.

B.

Replace pulse canister.

 

C.

Control does not work.

C.

Replace control.

 

 

 

 

 

1019490-5-C

12

Kohler Co.

Page 12
Image 12
Kohler K-812-N1 manual Troubleshooting