Grounding the Wall Plate
30
Each wire protrudes 9mm in length from the plastic insul ati on so th at it
can be easily connected. To prevent the wires crossing, be sure that each
wire is completely inserted
With STP cable, the GND pin is used for shielding. Shielding is not
needed, but if desired, connect to the GND pin of the PC
8.3 Cabling for the SV-306 and SV-307
Kramer engineers have developed special twisted pair cables to best match
our digital twisted pair products; the Kramer BCP-DGKat524 (CAT 5 24
AWG), and the Kramer BCP-DGKat623 (CAT 6 23 AWG cable). These
specially built cables significantly outperform regular CAT 5/CAT 6 cables.
A system range of up to 90m (295ft) at 1080i/SXGA, or up to 30m (98ft) at
1080p/UXGA on shielded BCP-DGKat524 cable; 90m (295ft) at 1080i, or
up to 70m (230ft) at 1080p/UXGA on shielded BCP-DGKat623 cable.
Note that the STP cable Ground shield must be connected/soldered to the
connector shield.
9 Grounding the Wall Plate
The grounding screw is used to earth the cha ssis of the unit to the ground of
the building, thus preventing static electricity from interfering with the
product’s performance.
Table 15 defines the grounding screw components.
Table 16: Grounding Screw, Lock Washers and Ring Tongue Terminal
# Item
1 M3X6 screw
2 1/8" Toothed Lock Washer
3 M3 Ring Tongue T erminal
To ground a wall plate:
1. Connect the Ring T ongue terminal to the building groundin g point wire
(it is recommended to use a green-yellow AWG#18 wire, crimped with a
proper hand-tool).
2. Insert the M3x6 sc rew through the toothed lock washers and the tongue
terminal in the order shown above.
3. Insert the M3x6 screw (with the two toothed lock washers a nd ring
tongue terminal) into the grounding scre w hole and tighten the screw.