KRAMER: SIMPLE CREATIVE TECHNOLOGY

Table of Hex Codes for Serial Communication

12

8 Table of Hex Codes for Serial Communication

Table 6 lists the Hex values for a single machine (MACHINE # 1). 4 bytes of

information are sent for each instruction. For more detailed information, see

Protocol 2000

1

.

Table 6: VP-108 Hex Codes

VIDEO
2
:
OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 ALL OUTPUTS
ON 





2



3



4



5



6



7



8





OFF

0



0
2


0
3


0
4


0



0



0



0



0


AUDIO
3
:
OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 ALL OUTPUTS
ON 2



2

2

2

3

2

4

2

5

2

6

2

7

2

8

2



OFF
2
0


2
0
2

2
0
3

2
0
4

2
0


2
0


2
0


2
0


2
0


1 On our Web site at http://www.kramerelectronics.com
2 For audio-follow-video mode
3 For audio breakaway mode