8 Default Communication Parameters

RS-232

Protocol 2000 (Default)

Protocol 3000

 

 

 

Baud Rate

 

 

9600

Baud Rate

 

9600

 

Data Bits

 

 

8

Data Bits

 

8

 

 

 

 

 

 

 

 

 

 

 

Stop Bits

 

 

1

Stop Bits

 

1

 

Parity

 

 

None

Parity

 

None

 

 

 

 

 

 

 

 

Command Format

HEX

Command Format

ASCII

 

 

 

 

 

 

 

 

Example (Output

0x01, 0x81, 0x81, 0x81

Example (Output 1 to

#VID1>1<CR>

1 to Input 1)

 

 

 

Input 1)

 

 

 

 

 

 

 

 

 

 

 

 

Switching Protocol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2000 –> P3000

 

 

 

P3000 –> P2000

 

 

 

 

 

 

 

 

 

 

Command

 

0x38, 0x80, 0x83, 0x81

Command

 

#P2000<CR>

 

 

 

 

 

 

 

Front Panel

 

Press and hold Output 1 and

Front Panel

 

Press and hold Output 1

 

 

Output 3 simultaneously

 

 

and Output 2 simultaneously

 

 

 

 

 

 

 

 

 

Ethernet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP Address

 

 

192.168.1.39

TCP Port

 

5000 or 10001 or 50000

Subnet Mask

 

 

255.255.255.0

UDP Port

 

50000

 

 

 

 

 

 

 

 

 

 

 

 