7.Select the output from which the EDID is acquired (for example, OUT 6).
8.Press the IN 3 button.
The IN 3 button stops flashing.
9.Press the input buttons to which you want to copy the EDID (for example, IN 1 and IN 3).
10.Make sure that the relevant input numbers flash on the display.
11.Press the EDID button.
The process is complete when the display returns to normal.
6.2.3Acquiring the Default EDID
To store the default EDID on a selected input (for example, Input 2):
1.Press the EDID and STO buttons simultaneously and hold them for 3 seconds.
Both buttons flash.
2.Press the input (for example, Input 2) to which the EDID is to be copied. The selected input number flashes on the display.
3.Press the OFF button until "0" (zero) appears on the display.
4.Press the EDID button.
The default EDID is stored on the selected input when the display returns to normal.
6.3Storing and Recalling a Preset
You can use the STO and RCL buttons to store up to 12 setups and then recall them using the OUT
Figure 4: |
|
| 13 |