7 Capturing the EDID from a Display Device
To capture the EDID from a display device:
1.Using a Philips screwdriver, remove the four screws holding the faceplate to the PCB assembly.
2.Using a short cable (for example, Kramer model number
3.Ensure that the rotary switch (see Figure 8) is in position 0. If it is not, use a small screwdriver to turn it to 0.
4.Connect the 12V DC power adapter to the power terminal block (see Figure 4) on the
5.Press the EDID capture button (see Figure 8).
The EDID status LED flashes slowly several times. The new EDID is captured when the LED stops flashing and lights solid.
6.Unplug the power adapter from the mains and disconnect it from the
7.Replace the faceplate and secure the four screws removed in Step 1.
To set a preconfigured EDID:
1.Using a Philips screwdriver, remove the four screws holding the front panel to the rear PCB assembly.
2.Using a small screwdriver, turn the rotary switch (see Figure 8) to the required position as defined in the table below.
3.Connect the 12V DC power adapter to the power terminal block (see Figure 4) on the
12 |