C) HF Level Adjust
This is a
D) LF Adjust
This is a low frequency boundary adjustment switch designed to optimize linear bandwidth in your environment. This switch compensates for proximity to wall areas that may create undesirable increases in bass response and, in the process, create
E) Voltage Select Switch for AC Mains
This switch provides four voltage options that your E8B loudspeaker will operate within. The loudspeaker will operate at 100V, 120V (North America), 230V, and 240V (Europe). If you operate in a 230V environment, please use the 240V setting. This switch is tied to the adjacent fuse compartment. If you are operating in a 100V or 120V environment, please use a fuse rated at
Connecting Your System
Before powering your monitors on, please take a moment to ensure the Voltage Select Switch for the AC Mains is set to match your location. At this point, all connections should be made, all faders and controls should be set to their minimum levels, and all other equipment should be powered on prior to powering on your Exposé E8B monitors.
The power On/Off switch is located on the rear panel and is internationally marked to indicate the operational status. ( — ) = ON and ( O ) = OFF. An LED illuminates the KRK Logo on the front baffle when power is applied.
Balanced XLR Connector
The Exposé E8B monitors use a single balanced XLR
• Pin 1: Ground
• Pin 2: Hot / (+)
• Pin 3: Cold /
7