KRK ROKIT POWERED SERIES manual Systems Control, Connecting Your System

Models: ROKIT POWERED SERIES

1 11
Download 11 pages 38.42 Kb
Page 5
Image 5
Systems Control

• 1" neo soft dome tweeter with ferrofluid

8" glass aramid composite cone woofer

140W biamp w/18dB oct. filters

Optimized directivity high frequency waveguide

Magnetically shielded

• Freq. Response: 45Hz to 20kHz

160W

Designed and Engineered in the U.S.A.

Made in China

Systems Control

SYSTEM VOLUME

The input sensitivity is adjusted (counterclockwise reduces sensitivity) with the rear panel mounted System Gain control. Adjustment range is from - 30dB to +6dB. Factory preset gain is +6dB, which should suffice for most conditions. Normally adjust- ments would only be made if you’re using your moni- tor in a surround system and need to balance levels or if your monitor send is too hot and not adjustable.

HF ADJUSTMENT (TWO-WAY SYSTEMS)

High Frequency Adjustment is through a rear panel mounted 4-position rotary switch. Range of control is +1dB, Flat, -1dB ,or -2dB shelving above 2 kHz. Factory setting for your RoKit Powered Monitor is flat (switch is in 0dB position). Room acoustics may dic- tate which type of adjustment you need to make to retain a flat frequency response from the monitor. (See additional information in Installing Your Monitors section on page 4.)

Connecting Your System

POWERING ON

All connections should be made, all fader and controls should be set at their minimum levels, and all other equip- ment should be powered on prior to powering on your Rokit monitors.

The power On/Off switch is located on the rear panel. A yel- low LED illuminates the trademarked KRK Triangle on the front baffle when power is applied.

NOTE: MAKE SURE THAT THE VOLTAGE INDICATOR

FOUND IN THE VOLTAGE SELECTOR IS SET TO THE

CORRECT VOLTAGE SETTING FOR YOUR VOLTAGE.

CHANGING VOLTAGE

160W

To change the voltage, remove the power cord, slide voltage selector to desired voltage setting. Please note when making

voltage changes, the fuses will have to be replaced. (see Changing Fuses section below)

CHANGING FUSES

Under normal operation the fuses should not blow. A blown fuse usually indicates an overload or fault condition. To change the fuse, remove the power cord, pry off the fuse block with a small flathead screwdriver and change the blown fuses.

Refer to specifications page 8 for fuse current ratings.

If the fuses blow immediately upon power up, this indicates a fault condition and the monitor should be returned to KRK for repair.

AUDIO INPUTS

The XLR and TRS are balanced inputs where as the rca input is an unbalanced input.

UNBALANCEDBALANCED

AUDIO INPUT

10K OHMS BALANCED PIN 2 + TIP = HIGH PIN 3 + RING = LOW

PIN 1 + SLEAVE = GROUND

RCA

TRS 1/4”